Rms2Mh080

8 Intel® Integrated RAID Module RMS2MH080 Hardware User’s Guide
Figure 1. Installing the Barrel Standoff
4. Attach the Intel
®
Integrated RAID Module RMS2MH080 module card to the
matching server/workstation board connector, and press the module card firmly to
engage the barrel standoffs installed in step 3 (see
Figure 2).
5. Press down gently but firmly to ensure that the card is properly seated in the
connectors, and then insert the three pin standoffs into the barrel standoffs
respectively ( see
Figure 2).
Figure 2. Installing the Intel
®
Integrated RAID Module RMS2MH080
6. Connect the SAS/SATA cables from the backplane (or hard drives) to the RAID
module (see
Figure 3). For information regarding connecting the recommended
Right-angle end or Vertical end of the SAS/SATA cable to the SAS connectors of
the controller, see your server/workstation board or chassis documentation. Make
sure the cables are properly connected to the controller.
Note: System throughput problems can occur if non-standard SAS cables are used.
To minimize the potential for problems:
AF003481