Monthly Specification Update

Enterprise Platforms and Services Marketing Monthly Specification Update
3
Summary Tables of Changes
The following tables provide an overview of known errata and known document changes that
apply to the specified Intel Server Products. The tables use the following notations:
Doc:
Intel intends to update the appropriate documentation in a future revision.
Fix:
Intel intends to fix this erratum in the future.
Fixed:
This erratum has been previously fixed.
No Fix:
There are no plans to fix this erratum.
Shaded:
This erratum is either new or has been modified from the previous specification
update.
Table 1. Errata Summary
No.
Plans
Description of Errata
1.
Fix:
Errors are reported during the installation of SuSE* SLES 10 EM64T
2.
Fix:
Hyper-Threading cannot be disabled in BIOS setup
3.
No Fix:
A critical interrupt is logged in the System Event Log (SEL) when installing SuSE* SLES 10 32-bit
4.
No Fix:
Wake on LAN (WOL) does not work on 1GB IO Modules
5.
Fixed:
Is SATA compatabiltiy mode, the operating system may take more than four hours to install
6.
Fix:
Serial Console may display extra text or intermingled text
7.
Fix
The PXE boot option is missing in BIOS setup
8.
Fix
Fans may boost temporarily when the BMC is under load
9.
Fix
Extra events may be seen in the SEL during system reset
10.
Fix
BIOS setup may report incorrect firmware versions
11.
Fix
Hard drive status LED for blank drive slots may blink amber when system is in AHCI mode
12.
No Fix
If the server board battery is missing, firmware will detect it as present and good
13.
Fix
Server board can’t detect a 10Gb or QDR IB IO Module without a PCI Riser installed
14.
Fixed
Cannot Update DVD Drive Firmware when 6 DIMMs are installed
15.
Fix
Closed Loop Thermal Throttling (CLTT) is not automatically detected and set when using
unbuffered memory (UDIMMs)
16.
Fixed
Intel Deployment Assistant cannot be used to perform unattended Windows OS installs
17.
Fix
DCMI Capabilities test failure: Temperature Sensor Discovery
18.
Fix
DCMI Capabilities test failure: VLAN Support test
19.
Fix
DCMI conformance test failure: LAN configuration ARP control
20.
Fix
System Hangs when AXX4SASMOD I/O Module set to ESRTII
21.
No Fix
Dual Display Not Working In SuSE* 10 32-bit
22.
Fix
Excessive Time to Enter or Exit EFI Shell When AHCI is Enabled in BIOS Revision R0037
23.
Fix
Error numbering of SATA ports in TPS rev1.0
24.
Fix
Error numbering of SATA ports in Quick Reference Label
25.
Fix
Error numbering of SATA ports in Quick Start User Guide
26.
No Fix
HDD status LED on HDD carrier will light as bright amber during rebuild
27.
Fix
Port 1, 2, 3 fault LED (Amber) on HDD backplane will be flashing during POST