Implication Certain Power supply information is not available (blank) in the Intel
®
Active
System Console
Predictive PS failure data (Internal voltage levels and fan speed)
Power supply temperature data
Power Supply FRU information
FRUSDR utility can’t detect the presence of Power Supply Unit when updating
the system SDRs and will report “PS1 not found” message when loading the
SDR.
The dedicated power management applications based on the Intel
®
Management Engine (ME) like Intel
®
Node Manager (NM) and Data Center
Manager (DCM) are not affected by this issue on the Intel
®
Server System
SR1690WB.
Status Will Not Fix.
Workaround If required an optional in-line adapter can be installed between the server
board and power supply to correct the communication timing and enable the
sensors. For more information on this issue please contact your Intel Sales
Representative
33. Intel
®
Server System SR1695WB may record a System Event Log (SEL)
entry during an unexpected power loss
Problem System may record the following System Event Log (SEL) entry if power is lost
unexpectedly:
Voltage /BB +12.0V (#0x1B) Lower Non-critical - going low. Trigger Threshold
= 0xD2. Asserted Event. BMC - LUN #0 (Channel #00h)
Implication This SEL entry does not have any functional impact to the system.
Status No Fix.
Workaround It will be fixed in new PSU firmware release. Customer can ignore this SEL
entry currently.
34. Intel
®
Server System SR1695WB Quick Star Users Guide (QSUG)
doesnt show two Power Supply Units (PSU) for AC sku
Problem Intel
®
Server System SR1695WB Quick Start Users Guide (QSUG) doesnt
show two Power Supply Units (PSU) for AC sku.
Implication The back panel drawing of AC sku in QSUG shows only one PSU. It doesnt
match real system which has two PSUs installed.
Status Fixed from QSUG E92845-002.