Monthly Specification Update

Enterprise Platforms and Services Marketing Monthly Specification Update
11
19. DCMI conformance test failure: LAN configuration ARP control
Problem The DCMI conformance test may report a failure when testing the BMC’s ARP
control parameters. The BMC does not support gratuitous ARP generation.
Implication The DCMI conformance test suite will report a failure. The BMC can only
support ARP responses, but gratuitous ARP messages are not supported by
the BMC.
Status This issue is fixed in BMC 38.
Workaround None
20. System Hangs when AXX4SASMOD I/O Module set to ESRTII
Problem In BIOS set the Intel SAS Entry RAID (AXX4SASMOD) module to Enabled and
set the Configure Intel SAS Entry RAID to Intel ESRTII. When the system
resets it will hang before video appears.
Implication Only the IT/IR mode will work with the AXX4SASMOD module. Use BIOS
Reset jumper to recover from setting ESRTII mode. This will set the BIOS
defaults allowing the system to boot.
Status This issue may be fixed in a future BIOS release.
Workaround None
21. Dual Display Not Working In SuSE* 10 32-bit
Problem Dual display does not work when starting the GUI. It fails with the error
message, "Fatal server error: Caught signal 11. Server aborting.".
Implication The video would work through one port on the add-in card but not on the
onboard video and the add-in card at the same time. This only affects the 32-
bit OS. The 64-bit version of the OS works after editing the xorg.conf file.
Status This issue will NOT be fixed.
Workaround Use 64-bit OS.