Status This issue may be fixed in a future BMC release.
Workaround None
10. BIOS setup may report an incorrect firmware versions
Problem The BIOS setup screens to display the versions of SDR and ME firmware
version may report an incorrect version. The version displayed may be of the
previously installed versions.
Implication After firmware update, the BIOS screens may not show the correct version until
the system is AC cycled.
Status This issue may be fixed in a future BMC release.
Workaround None
11. Hard drive status LED for blank drive slots may blink amber when
system is in AHCI mode
Problem The hard drive status LEDs for empty drive slots may blink amber when the
system is operating in AHCI mode.
Implication The hard drive status LED may indicate a false status for an unpulated drive
slot.
Status This issue may be fixed in a future BIOS or BMC release.
Workaround None
12. If the Server Board battery is missing, firmware will detect it as
present and good
Problem The firmware will detect a serverboard battery as present and good when it is
missing.
Implication A missing battery will not be reported. If a battery is present, it will still accuratly
report the health of the battery. Problem is only seen when the battery is
missing.
Status This issue will NOT be fixed.