Hardware User's Guide

Intel® Integrated RAID Module RMS2MH080 Hardware User’s Guide 7
2 Intel
®
Integrated RAID Module
RMS2MH080 Hardware Installation
Requirements
Intel
®
Integrated RAID Module RMS2MH080, with the provided standoffs
A host system with two available 50-pins PCI Express* 2.0 connector
Resource CD, which contains drivers and documentation
SAS or SATA 6.0 hard drives up to 6Gb/s speed
Provided SAS/SATA cables (for cable requirements, see step 6 in “Installing the
RAID Module”)
Note: Intel Corporation strongly recommends using an uninterruptible power supply (UPS).
Installing the RAID Module
To install the RAID Module, follow these steps:
1. Turn off the power to the system, all drives, enclosures, and system components.
Remove the power cord(s).
2. Remove the server cover. For instructions, see your server system documentation.
3. Insert the three barrel standoffs into the matching holes in the server/workstation
board. To locate the matching module card slot on your server/workstation board,
see your server/workstation board documentation.
The Intel
®
Server Board SR5520UR is shown for illustrative purpose. Actual
standoff hole locations could be different (see
Figure 1).