Technical Product Specification
Environmental and Regulatory Specification Intel® Server System SR1690WB TPS
Revision 1.7
Intel order number: E72797-009
46
English translation of the notice above:
This is a Class A product based on the standard of the Voluntary Control Council For
Interference (VCCI) from Information Technology Equipment. If this is used near a radio or
television receiver in a domestic environment, it may cause radio interference. Install and
use the equipment according to the instruction manual.
10.6.5 BSMI (Taiwan)
The BSMI Certification number and the following warning is located on the product safety
label which is located on the bottom side (pedestal orientation) or side (rack mount
configuration).
10.6.6 KCC (Korea)
Following is the KCC certification information for Korea.
인증번호 : CPU-SR1690 (A)
10.7 Rack Mount Installation Guidelines
Anchor the equipment rack: The equipment rack must be anchored to an unmovable support
to prevent it from falling over when one or more servers are extended in front of the rack on
slides. You must also consider the weight of any other device installed in the rack. A crush
hazard exists should the rack tilt forward which could cause serious injury.
Temperature: The temperature, in which the server operates when installed in an equipment
rack, must not go below 5 °C (41 °F) or rise above 40 °C (104 °F). Extreme fluctuations in
temperature can cause a variety of problems in your server.
Ventilation: The equipment rack must provide sufficient airflow to the front of the server to
maintain proper cooling. The rack must also include ventilation sufficient to exhaust a
maximum of 1023 BTUs (British Thermal Units) per hour for the server. The rack selected
and the ventilation provided must be suitable to the environment in which the server will
be used.