Technical Product Specification
Intel® Server System SR1690WB TPS 2BPower Sub-System
Revision 1.7 13
Intel order number: E72797-009
Table 10. AC Input Rating
Parameter Min. Rated Max.
Max. input current at
Min. Vrms
Voltage (100)
90 V
rms
100 V
rms
110 V
rms
6.7 A
rms
Voltage (120)
108 V
rms
120 V
rms
132 V
rms
5.6 A
rms
Voltage (240)
180 V
rms
200-240 V
rms
264 V
rms
3.4 A
rms
Frequency
47 Hz
63 Hz
3.4.1 AC Line Transient Specification
AC line transient conditions are defined as “sag” and “surge” conditions. Sag conditions are
also commonly referred to as a “brown-out”. These conditions are defined as the AC line
voltage dropping below nominal voltage conditions. Surge refers to conditions when the AC
line voltage rises above nominal voltage.
The power supply meets the requirements under the following AC line sag and
surge conditions.
Table 11. AC Line Sag Transient Performance
AC Line Sag
Duration
Sag
Operating AC Voltage
Line Frequency
Performance Criteria
Continuous
10%
Nominal AC Voltage
ranges
50/60 Hz
No loss of function or performance
0 to 1 AC
cycle
100% Nominal AC Voltage
ranges
50/60 Hz No loss of function or performance
> 1 AC cycle
>10%
Nominal AC Voltage
ranges
50/60 Hz
Loss of function acceptable, self
recoverable
Table 12. AC Line Surge Transient Performance
AC Line Surge
Duration
Surge
Operating AC Voltage
Line Frequency
Performance Criteria
Continuous
10%
Nominal AC Voltages
50/60 Hz
No loss of function or performance
0 to ½ AC
cycle
30%
Mid-point of nominal AC
Voltages
50/60 Hz
No loss of function or performance
3.4.2 Susceptibility Requirements
The power supply meets the following electrical immunity requirements:
Table 13. Performance Criteria
Level Description
A The apparatus shall continue to operate as intended. No degradation of performance.
B
The apparatus shall continue to operate as intended. No degradation of performance
beyond spec limits.
C Temporary loss of function is allowed provided the function is self-recoverable or can be
restored by the operation of the controls.
3.4.2.1 Electrostatic Discharge Susceptibility
The power supply complies with the limits defined in EN 55024: 1998 using the IEC 61000-
4-2:1995 test standard and performance criteria B defined in Annex B of CISPR 24.Tested to
meet the level 3 requirement.