Service Guide
67
Appendix A: Technical Reference
650-W Single Power Supply Input Voltages
• 100-127V at 47/63 Hz; 8.6 A max.
• 200-240V at 47/63 Hz; 4.3 A max.
650-W Single Power Supply Output Voltages
The following table lists the total wattage available from the power subsystem for each
voltage. Ensure your loads do not exceed the combined total wattage of 650 W. For
information about calculating the power usage for your configuration, see “Power Budget
Tool.”
Table 7. 650-W Single Power Supply Output Voltages
1. Maximum continuous total DC output power should not exceed 650 watts.
2. Peak load on the combined 12V output shall not exceed 52A peak.
3. Maximum continuous load on the combined 12V output shall not exceed 47A
4. Peak total DC output power should not exceed 700 Watts peak.
5. Peak power and peak current loading shall be supported for a minimum of 12
seconds.
6. Combined 3.3V & 5V power shall not exceed 150W.
Voltage Maximum Continuous
+3.3 V 13.8A
+5 V 19.6A
+12 V1 11.3A
+12 V2 11.3A
+12 V3 9.1A
+12 V4 9.1A
-12 V 0.43A
+5 VSB 3.0A