Datasheet
Intel® Server Board S5520HC / S5500HCV TPS Appendix C: BMC Sensor Tables
Revision 1.2
Intel order number E39529-009
159
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event /
Reading
Type
Event Offset
Triggers
Contrib. To
System
Status
Assert /
De-
assert
Readabl
e
Value /
Offsets
Event
Data
Rearm
Stand-
by
Power Supply 2
AC Power Input
(PS2 Power In)
53h
Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
Power Supply 1 +12V % of
Maximum Current Output
(PS1 Curr Out %)
54h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
Power Supply 2 +12V % of
Maximum Current Output
(PS2 Curr Out %)
55h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
Power Supply 1
Temperature
(PS1 Temperature)
56h
Chassis-
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
Power Supply 2
Temperature
(PS2 Temperature)
57h
Chassis-
specific
Temperature
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X
01 - Thermal trip Fatal
Processor 1 Status
(P1 Status)
60h All
Processor
07h
Sensor
Specific
6Fh
07 - Presence OK
As and
De
– Trig Offset M
X
01- Thermal trip Fatal
Processor 2 Status
(P2 Status)
61h
Dual
processor
only
Processor
07h
Sensor
Specific
6Fh
07 - Presence OK
As and
De
– Trig Offset M
X
Processor 1 Thermal
Margin
(P1 Therm Margin)
62h All
Temperature
01h
Threshold
01h
– – – Analog – – –
Processor 2 Thermal
Margin
(P2 Therm Margin)
63h
Dual
processor
only
Temperature
01h
Threshold
01h
– – – Analog – – –