Datasheet
Appendix C: BMC Sensor Tables Intel® Server Board S5520HC / S5500HCV TPS
Revision 1.2
Intel order number E39529-009
158
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event /
Reading
Type
Event Offset
Triggers
Contrib. To
System
Status
Assert /
De-
assert
Readabl
e
Value /
Offsets
Event
Data
Rearm
Stand-
by
05 - Non-
redundant:
insufficient
resources.
Non-fatal
06 – Non-
Redundant:
degraded from
fully redundant.
Degraded
07 - Redundant
degraded from
non-redundant
Degraded
00 - Presence OK
01 - Failure Degraded
02 – Predictive
Failure
Degraded
03 - A/C lost Degraded
Power Supply 1 Status
(PS1 Status)
50h
Chassis-
specific
Power Supply
08h
Sensor
Specific
6Fh
06 –
Configuration
error
OK
As and
De
– Trig Offset A X
00 - Presence OK
01 - Failure Degraded
02 – Predictive
Failure
Degraded
03 - A/C lost Degraded
Power Supply 2 Status
(PS2 Status)
51h
Chassis-
specific
Power Supply
08h
Sensor
Specific
6Fh
06 –
Configuration
error
OK
As and
De
– Trig Offset A X
Power Supply 1
AC Power Input
(PS1 Power In)
52h
Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As and
De
Analog R, T A X