Intel® Server System SR1630BC Technical Product Specification Intel order number E44588-005 Revision 1.
Revision History Intel® Server System SR1630BC TPS Revision History Date January 2009 Revision Number 1.0 Modifications Initial Release March 2009 1.1 Updated system feature set table April 2009 1.2 Updated Appendix B: POST Code Diagnostic LED Decoder according to BIOS EPS. Updated Appendix C: POST Error Messages and Handling according to BIOS EPS. Updated “System Status LED Indicator States Table”. Removed AXXHERAL option from “Rack and Cabinet Mounting Options” section.
Intel® Server System SR1630BC TPS Disclaimers Disclaimers Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document.
Table of Contents Intel® Server System SR1630BC TPS Table of Contents 1. 2. Introduction............................................................................................................................. 1 1.1 Chapter Outline ......................................................................................................... 1 1.2 Server System Use Disclaimer ................................................................................ 1 Product Overview............................
Intel® Server System SR1630BC TPS 4.3 5. 6. Table of Contents Processor Air Duct and Air Baffle ............................................................................. 21 Peripheral and Hard Drive Support......................................................................................... 22 5.1 Optical Drive Support............................................................................................... 23 5.2 Hard Disk Drive Support .................................................
List of Figures Intel® Server System SR1630BC TPS List of Figures Figure 1. Intel® Server System SR1630BC................................................................................... 4 Figure 2. Major System Components – Intel® Server System SR1630BC ................................... 5 Figure 3. Back Panel Features ..................................................................................................... 6 Figure 4. Drive Bays – Intel® Server System SR1630BC ............................
Intel® Server System SR1630BC TPS List of Tables List of Tables Updated memory description in “Table 1: System Feature Set”. .................................................. ii Table 1. System Feature Set ........................................................................................................ 2 Table 2. Intel® Server System SR1630BC Dimensions ................................................................ 4 Table 3. Board Layout reference ...............................................
Introduction 1. Intel® Server System SR1630BC TPS Introduction This Technical Product Specification (TPS) provides system specific information detailing the features, functionality, and high level architecture of the Intel® Server System SR1630BC. You should also reference the Intel® Server Board S5500BC Technical Product Specification more details regarding the functionality and architecture specific to the integrated server board and what is supported in this server system.
Intel® Server System SR1630BC TPS 2. Product Overview Product Overview The Intel® Server System SR1630BC is a 1U server system designed to support the Intel® Server Board S5500BC. The server board and the system have features designed to support the high-density server market. This chapter provides a high-level overview of the system features. Greater detail for each major system component or feature is provided in the following chapters. Table 1.
Product Overview Intel® Server System SR1630BC TPS Feature Description Add-in PCI, PCI Express* Cards Slot6 on server board supports one riser card supporting one half-length low-profile (6.
Intel® Server System SR1630BC TPS 2.1 Product Overview System Views Figure 1. Intel® Server System SR1630BC 2.2 System Dimensions Table 2. Intel® Server System SR1630BC Dimensions 4 Height 1.7 inches Width without rails 16.9 inches Depth without CMA 20 inches Maximum weight 22 pounds Intel order number E44588-005 Revision 1.
Product Overview 2.3 Intel® Server System SR1630BC TPS System Components A Rack handles (two) F CPU Heatsink (two) B Processor air duct G System blower fans (two) C System memory DIMM sockets H Hard drives (two) D PCI add-in card bracket I Control panel E Power supply J Slimline optical drive Figure 2. Major System Components – Intel® Server System SR1630BC Note: The I/O connector locations on the back of the chassis are pre-cut, making an I/O shield unnecessary.
Intel® Server System SR1630BC TPS A Product Overview AC Power Connector E NIC 2 Connector (10 / 100 / 1000 Mb) BMC Management Port B Serial Port A F USB Ports 6 and 7 C Video Connector G USB Ports 8 and 9 D NIC 1 Connector (10 / 100 / 1000 Mb) H PCI Express* Slot Figure 3. Back Panel Features 6 Intel order number E44588-005 Revision 1.
Product Overview 2.4 Intel® Server System SR1630BC TPS Hard Drive and Peripheral Bays The Intel® Server System SR1630BC is designed to support up to two fixed 3.5-inch Serial ATA (SATA) hard drives and one slimline optical device. A Slimline optical drive bay B Hard drive bay HDD0 (located under the slimline optical drive bay) C Hard drive bay HDD1 Figure 4. Drive Bays – Intel® Server System SR1630BC Revision 1.
Intel® Server System SR1630BC TPS 2.5 Product Overview Server Board Overview Figure 5. Intel® Server Board S5500BC picture 8 Intel order number E44588-005 Revision 1.
Product Overview Intel® Server System SR1630BC TPS 2.5.1 Server Board Connector and Component Layout The following figure shows the board layout of the server board. Each connector and major component is identified by a number or letter, and a description is below the figure. Figure 6. Intel® Server Board S5500BC Layout Table 3. Board Layout reference A SATA 3 Description B Description Internal dual port USB2.
Intel® Server System SR1630BC TPS Product Overview Q Description System fan 3 header R Main power connector Description S DIMM sockets for Channel A & B (Supports CPU_1) T Power Supply Auxiliary Connector U SSI 24-pin Front Panel connector V System fan 2 header W CPU_1 fan header X CPU Power Connector Y CPU_1 Socket Z Intel® IOH 5500 chipset AA CPU Socket 2 BB CPU 2 fan header CC System fan 1 header DD DIMM sockets for Channels D and E (Supports CPU_2) EE SATA SGPIO FF SATA
Product Overview Intel® Server System SR1630BC TPS Table 4. Intel® Light-Guided Diagnostic LED reference 2.5.
Intel® Server System SR1630BC TPS 3. Power Sub-System Power Sub-System The power sub-system consists of one, non-redundant high efficiency 400-W power supply that supports a 1U rack mount server system. The power supply and the power supply sub-system will have six outputs: 3.3 V, 5 V, 12 V1, 12V2, -12 V, and 5 VSB. The input is auto-ranging and power factor corrected. The form factor is EPS1U at 240 mm depth and wire harness output.
Power Sub-System Intel® Server System SR1630BC TPS Figure 9. Power Supply Mechanical Drawing Notes: 1. All dimensions are in mm. 2. The tolerance of the 40 mm height dimension (marked with letter C) pertains to the metal case only. Revision 1.
Intel® Server System SR1630BC TPS Power Sub-System 3.2 Output Connectors The power supply has a cable harness with five power connectors used to power various platform sub-systems. The following table defines each power connector. Table 5. Cable Harness Definition 3.2.
Power Sub-System Intel® Server System SR1630BC TPS Table 7. P2 – Processor/DDR3 Power Connector Pin-out 3.2.3 Pin 1 Signal COM 18 Awg Color Black Pin 5 Signal +12V1 18 Awg Color Yellow 2 COM Black 6 +12V1 Yellow 3 COM Black 7 +12V1 Yellow 4 COM Black 8 +12V1 Yellow P3 – Power Signal Connector Connector housing: 5-pin Molex* 50-57-9705 (94V2) or equivalent Contacts: Molex* 16-02-0087 or equivalent Table 8. P3 –Power Signal Connector Pin-out Pin Signal 1 3.2.
Intel® Server System SR1630BC TPS 3.2.5 Power Sub-System P6 – Slim-line SATA Optical Disk Drive Power Connector Connector housing: 6-pin SATA Power Contact: 15u plating minimum Table 10. P6 – Slim-line SATA Optical Disk Drive Power Connector Pin-out Pin Signal 22 AWG Color 1 Reserved N.C. 2 +5 VDC Red 3 +5 VDC Red 4 Reserved N.C. 5 COM Black 6 COM Black 3.3 Efficiency The following table provides the required minimum efficiency level at various loading conditions.
Power Sub-System 3.5 Intel® Server System SR1630BC TPS Protection Circuits Protection circuits inside the power supply should cause only the power supply’s main outputs to shut down. If the power supply latches off due to a protection circuit tripping, an AC cycle off for 15 seconds and a PSON# cycle high for 1 second should be able to reset the power supply. 3.5.1 Over-current Protection (OCP) The power supply should have current limit to prevent the +3.
Intel® Server System SR1630BC TPS 3.5.3 Power Sub-System Output Voltage +12 V1,2 Minimum (V) 13.3 Maximum (V) 14.5 -12 V -13.3 -14.5 +5 VSB 5.7 6.5 Over-temperature Protection (OTP) The power supply is protected against over temperature conditions caused by loss of fan cooling or excessive ambient temperature. In an OTP condition, the power supply shuts down.
Cooling Sub-System 4. Intel® Server System SR1630BC TPS Cooling Sub-System The cooling sub-system consists of two 97 x 94 x 33mm blower fans and a system air duct. These components provide the necessary cooling and airflow to the system. A fan on the processor heatsink is not needed. You must properly install the air duct and the top cover to maintain the required airflow within the system. Note: The Intel® Server System SR1630BC does not support redundant cooling.
Intel® Server System SR1630BC TPS Cooling Sub-System Table 15. Cooling Zones Cooling Zone CPU2 Fan System fan blower left System fan blower right 4.1.1 CPU1 Greatest Cooling Influence Primary cooling for CPU2, system memory, and PCIE card on riser card Primary cooling for CPU1, IOH, and system memory System Fan Connectors ® The Intel Server System SR1630BC supports two system fan blowers. The pin-out for the connector is provided in the following table. Table 16.
Cooling Sub-System 4.2 Intel® Server System SR1630BC TPS Power Supply Fans The power supply incorporates two, non-redundant 40 mm fans for self-cooling. They are responsible for the cooling of the power supply. 4.3 Processor Air Duct and Air Baffle The system requires the use of the system air duct to direct airflow and sustain appropriate air pressure. Figure 12. Air Duct for the Intel® Server System SR1630BC Revision 1.
Intel® Server System SR1630BC TPS 5. Peripheral and Hard Drive Support Peripheral and Hard Drive Support The Intel® Server System SR1630BC provides support for two fixed hard drive bays and one slim-line peripheral drive bay at the front of the system. The fixed hard drive bays are designed to support SATA 3.5-inch drives. Item Feature A Slimline optical drive bay B Hard drive bay HDD0 (located under the slim-line optical drive bay) C Hard drive bay HDD1 Figure 13.
Peripheral and Hard Drive Support 5.1 Intel® Server System SR1630BC TPS Optical Drive Support The system provides a slimline drive bay that you can configure for a SATA optical CD-ROM or a DVD / CD-R drive. Drives are mounted on a tray which allows for easy installation into and removal from the system. The drive assembly is inserted in to the slim-line drive bay. A SATA cable connects the drive assembly to a SATA connector on the server board. The slimline devices are not hot-swappable. 5.
Intel® Server System SR1630BC TPS 6. Front Control Panel Front Control Panel The standard control panel supports a power button, status LED, hard drive activity LED, and NIC 1 and NIC 2 activity LEDs. The control panel assembly comes pre-assembled into the system. The control panel assembly module slides into a predefined slot on the front of the system. Once installed, communication to the server board is achieved through a standard 24pin cable connected directly to the server board.
Front Control Panel Intel® Server System SR1630BC TPS LED Color Green Off Disk Activity State Random blink Off Description HDD access No hard disk activity The current limiting resistors for the power LED, system fault LED, and NIC LEDs are located on the Intel® Server Board S5500BC. 6.1.1 Power / Sleep LED Table 18. SSI Power LED Operation State Power Off Power Mode Non-ACPI LED Off Description System power is off, and the BIOS has not initialized the chipset.
Intel® Server System SR1630BC TPS Color State Criticality Amber Blink Non-critical Front Control Panel Description Non-fatal alarm – system is likely to fail: CATERR asserted. Critical temperature threshold asserted. Critical voltage threshold asserted. Critical fan threshold asserted. VRD hot asserted. Amber 6.1.3 Solid on SMI Timeout asserted. Fatal alarm – system has failed or shutdown: CPU Missing. Thermtrip asserted. Non-recoverable temperature threshold asserted.
Front Control Panel 7. Intel® Server System SR1630BC TPS PCI Riser Cards and Assembly The Intel® Server Board S5500BC provides one PCI Express* x8 slot which supports one riser card with one riser card slot. The riser card supports one low-profile, half-length PCI Express* x8 add-in card which consumes power less than 15 W. Figure 15. PCI Riser Card Assembly Revision 1.
Intel® Server System SR1630BC TPS Environmental and Regulatory Specifications 8. Environmental and Regulatory Specifications 8.1 System Level Environmental Limits The following table defines the system level operating and non-operating environmental limits. Table 20.
Environmental and Regulatory Specifications Intel® Server System SR1630BC TPS Table 21. System Maintenance Procedure Times Activity Remove cover Time Estimate 1 min Remove and replace hard disk drive 8.
Intel® Server System SR1630BC TPS 8.4 Environmental and Regulatory Specifications Product Regulatory Compliance The server chassis product, when correctly integrated per this guide, complies with the following safety and electromagnetic compatibility (EMC) regulations. Intended Application – This product was evaluated as Information Technology Equipment (ITE), which may be installed in offices, schools, computer rooms, and similar commercial type locations.
Environmental and Regulatory Specifications Intel® Server System SR1630BC TPS Note: The Intel® Server System SR1630BC meets Class A Certifications Emissions requirements. Table 22.
Intel® Server System SR1630BC TPS Compliance Regional Description Korea Environmental and Regulatory Specifications Compliance Reference RRL Certification MIC Notice No. 1997-41 (EMC) & 1997-42 (EMI) Russia GOST-R Certification GOST R 29216-91 (Emissions) GOST R 50628-95 (Immunity) Ukraine Ukraine Certification Taiwan BSMI CNS13438 Compliance Reference Marking Example 인증번호: CPU-Model Name (A) None Required R33025 32 Intel order number E44588-005 Revision 1.
Environmental and Regulatory Specifications 8.6 Intel® Server System SR1630BC TPS Electromagnetic Compatibility Notices 8.6.1 USA This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions related to the EMC performance of this product, contact: Intel Corporation 5200 N.E.
Intel® Server System SR1630BC TPS 8.6.2 Environmental and Regulatory Specifications FCC Verification Statement Product Type: SR1630; S5500BC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Environmental and Regulatory Specifications 8.6.7 Intel® Server System SR1630BC TPS RRL (Korea) Following is the RRL certification information for Korea. English translation of the notice above: 1. 2. 3. 4. 5. Type of Equipment (Model Name): On License and Product Certification No.: On RRL certificate.
Intel® Server System SR1630BC TPS Environmental and Regulatory Specifications Table 23. Product Ecology Compliance Reference Table Compliance Regional Description Compliance Reference California California Code of Regulations, Title 22, Division 4.5; Chapter 33: Best Management Practices for Perchlorate Materials. China China RoHS Administrative Measures on the Control of Pollution Caused by Electronic Information Products” (EIP) #39. Referred to as China RoHS.
Environmental and Regulatory Specifications Compliance Regional Description Intel Internal Specification International Intel® Server System SR1630BC TPS Compliance Reference All materials, parts and subassemblies must not contain restricted materials as defined in Intel’s Environmental Product Content Specification of Suppliers and Outsourced Manufacturers – http://supplier.intel.com/ehs/environmental.htm ISO11469 - Plastic parts weighing >25gm are intended to be marked with per ISO11469.
Intel® Server System SR1630BC TPS 8.8 Environmental and Regulatory Specifications Other Markings Compliance Description Stand-by Power Compliance Reference Compliance Reference Marking Example 60950 Safety Requirement Applied to product is stand-by power switch is used. . Multiple Power Cords 60950 Safety Requirement Applied to product if more than one power cord is used.
Appendix A: Integration and Usage Tips Intel® Server System SR1630BC TPS Appendix A: Integration and Usage Tips This section provides a list of useful information unique to the Intel® Server System SR1630BC that you should keep in mind while integrating the server system. • The Intel® Server System SR1630BC requires the use of a shielded LAN cable to comply with Immunity regulatory requirements.
Intel® Server System SR1630BC TPS Appendix B: POST Code Diagnostic LED Decoder Appendix B: POST Code Diagnostic LED Decoder The BIOS executes platform configuration processes during the system boot. Each process is assigned a specific hex POST code number. As each configuration routine is started, the BIOS displays the POST code on the POST Code Diagnostic LEDs on the back edge of the server board. The Diagnostic LEDs identify the last POST process to be executed.
Appendix B: POST Code Diagnostic LED Decoder Intel® Server System SR1630BC TPS Table 25. Diagnostic LED POST Code Decoder Diagnostic LED Decoder O = On, X=Off Checkpoint Upper Nibble Lower Nibble Description MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h LED #7 #6 #5 #4 #3 #2 #1 #0 Multi-use code – This POST Code is used in different contexts.
Intel® Server System SR1630BC TPS Appendix B: POST Code Diagnostic LED Decoder Diagnostic LED Decoder O = On, X=Off Checkpoint Upper Nibble Lower Nibble MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h LED #7 #6 #5 #4 #3 #2 #1 #0 0x52h X O X O X X O X 0x53h X O X O X X O O 0x54h X O X O X O X X 0x55h X O X O X O X O 0X56h X O X O X O O X 0x57h X O X O X O O O USB 0x58h X O X O O X X X 0x59h X O X O O X X O ATA/ATAPI/SATA 0x5Ah X O X O O X O X 0x5Bh X O X O O X O O SMBUS 0x5Ch X O X O O O X X 0x5Dh X O X O O O X O Local Co
Appendix B: POST Code Diagnostic LED Decoder Intel® Server System SR1630BC TPS Diagnostic LED Decoder O = On, X=Off Checkpoint Upper Nibble Lower Nibble Description MSB LSB 8h 4h 2h 1h 8h 4h 2h 1h LED #7 #6 #5 #4 #3 #2 #1 #0 0xD5 X O X O Trying to boot device selection 5 O O X O 0xD6 O O X O X O O X Trying to boot device selection 6 0Xd7 O O X O X O O O Trying to boot device selection 7 O X X X Trying to boot device selection 8 0xD8 O O X O 0xD9 O O X O O X X O Tryin
Intel® Server System SR1630BC TPS Appendix C: POST Error Messages and Handling Appendix C: POST Error Messages and Handling Whenever possible, the BIOS outputs the current boot progress codes on the video screen. Progress codes are 32-bit quantities plus optional data. The 32-bit numbers include class, subclass, and operation information. The class and subclass fields point to the type of hardware being initialized. The operation field represents the specific initialization activity.
Appendix C: POST Error Messages and Handling Intel® Server System SR1630BC TPS Error Code 0195 Error Message Processor 0x Intel(R) QPI speed mismatch. Response Major 0196 Processor 0x model mismatch. Fatal 0197 Processor 0x speeds mismatched. Fatal 0198 Processor 0x family is not supported. Fatal 019F Processor and chipset stepping configuration is unsupported. Major 5220 CMOS/NVRAM Configuration Cleared Major 5221 Passwords cleared by jumper Major 5224 Password clear Jumper is Set.
Intel® Server System SR1630BC TPS Appendix C: POST Error Messages and Handling Error Code 854B DIMM_F2 Disabled. Error Message Response Major 8560 DIMM_A1 Component encountered a Serial Presence Detection (SPD) fail error. Major 8561 DIMM_A2 Component encountered a Serial Presence Detection (SPD) fail error. Major 8562 DIMM_B1 Component encountered a Serial Presence Detection (SPD) fail error. Major 8563 DIMM_B2 Component encountered a Serial Presence Detection (SPD) fail error.
Appendix C: POST Error Messages and Handling Intel® Server System SR1630BC TPS Error Code 9506 Error Message ATA/ATPI component encountered a controller error. Response Minor 95A6 PCI component encountered a controller error. Minor 95A7 PCI component encountered a read error. Minor 95A8 PCI component encountered a write error. Minor 9609 Unspecified software component encountered a start error. Minor 9641 PEI Core component encountered a load error.
Intel® Server System SR1630BC TPS Appendix C: POST Error Messages and Handling In case of POST error(s) listed as Major, the BIOS enters the error manager and waits for the user to press an appropriate key before booting the operating system or entering the BIOS Setup. The user can override this option by setting the POST Error Pause option as disabled on the BIOS setup Main screen. If this option is disabled, the system boots the operating system without user intervention. The default is disabled.
Glossary Intel® Server System SR1630BC TPS Glossary Word / Acronym ACA Australian Communication Authority Definition ANSI American National Standards Institute BMC Baseboard Management Controller CMOS Complementary Metal Oxide Silicon D2D DC-to-DC EMP Emergency Management Port FP Front Panel FRB Fault Resilient Boot FRU Field Replaceable Unit LCD Liquid Crystal Display LPC Low-Pin Count MTBF Mean Time Between Failure MTTR Mean Time to Repair OTP Over-temperature Protection OVP
Intel® Server System SR1630BC TPS Reference Documents Reference Documents See the following documents for additional information: 50 • Intel® Server Board S5500BC Technical Product Specification • Intel® Server Board S5500BC / Intel® Server Chassis SC5650 / Intel® Server System SR1630BC Spares/Parts List and Configuration Guide • Intel® S5500 Chipsets Server Board BIOS External Product Specification Intel order number E44588-005 Revision 1.