Quick Start Guide Front Page

Intel is a registered trademark of Intel Corporation or its
subsidiaries in the United States and other countries.
*Other names and brands may be claimed as the
property of others. Copyright © 2009, Intel Corporation.
All rights reserved.
Warning
Read all caution and safety
statements in this document
before performing any of the
instructions. Also see the Intel
®
Server Board and Server Chassis
Safety Information document at:
http://support.intel.com/support/
motherboards/server/sb/cs-010770
.htm for complete safety information.
Warning
Installation and service of
this product should only be
performed by qualified service
personnel to avoid risk of injury from
electrical shock or energy hazard.
Tools Required
Caution
Observe normal ESD
[Electrostatic Discharge]
procedures during system
integration to avoid possible
damage to server board and/or
other components.
Anti-static
wrist strap
Phillips*
screwdriver
Intel
®
Server System SC5650BCDP
Quick Start User's Guide
1
Preparing
the Chassis
Observe normal ESD
(Electrostatic Discharge)
procedures.
Place your
Intel
®
Server Chassis on
a flat anti-static surface to
perform the following
integration procedures.
Always touch the chassis
frame first, before reaching
inside to make server
board connections or to
install components.
Minimum Hardware
Requirements
Processor:
Minimum of one Intel
®
Xeon
®
processor 5500 series
(except TDP 135 W)
Heat Sink:
2U active heat sink for each
processor installed.
Memory:
Minimum of one 1GB,
DDR3 800/1066/1333
MHz compliant 240-pin DIMM.
Hard Disk Drives:
SATA
Power:
Minimum of 600W.
Before proceeding further,
do the following:
IMPORTANT!
Check your Intel
®
Server System for
disconnected or loose cables and components
that may have occurred during shipping.
E79709-001
7
Install Memory DIMMs
To Install DIMMs:
This server board supports up to eight
DDR3-800/1066/1333 ECC RDIMM and ECC UDIMMs.
Memory Configurations and Population Order:
DIMM
notch and
socket
bump must
align as
shown.
Memory Type: Minimum of one 1GB 800/1066/1333 MHz compliant 240-pin DDR3 DIMM.
Memory sizing and configuration is supported only for qualified DIMMs approved by
Intel
®
. For a list of supported memory, see the tested memory list at
http://support.intel.com/support/motherboards/server/SC5650BCDP/compat.htm
DIMMs must be identical with respect to size, speed, and organization.
Note: For additional memory configurations, see the User Guide on the Intel
®
Server
Deployment Toolkit CD that accompanied your Intel
®
Server System SC5650BCDP,
or go to: http://support.intel.com/support/motherboards/server/SC5650BCDP
Open both DIMM socket levers.
Push down firmly on the DIMM until it
snaps into place and both levers close.
Insert DIMM making sure the connector edge
of the DIMM aligns correctly with the slot.
C
A
D
IMPORTANT! Visually check that each
latch is fully closed and correctly
engaged with each DIMM edge slot.
E
Note location of alignment notch.
B
CAUTION: Avoid touching contacts when
handling or installing DIMMs.
E
DDR3DDR3
Populate DDR3 DIMMs in the order of A1, D1, B1, E1, A2, D2, B2, E2.
Populate the farthest DIMM from the processor for per DIMM per channel.
A
C
D
B
DIMM_E1
DIMM_E2
DIMM_D1
DIMM_D2
DIMM_B1
DIMM_B2
DIMM_A1
DIMM_A2
DDR3 Memory Identification:
If you are not familiar with ESD (Electrostatic Discharge) procedures used
during system integration, please see the Intel® Server System SC5650BCDP
User's Guide, available on the Intel® Server Deployment Toolkit CD or at
http://support.intel.com/support/motherboards/server/S5500BC/howto.htm.
Read all cautions and warnings first before starting your server system integration.
Thank you for buying an Intel® Server System.
The following information will help you
assemble your Intel®
Server System
SC5650BCDP and install components.
This guide and other supporting documents
are located on the web at:
http://support.intel.com/support/motherboards/server/SC5650BCDP/
5
Install the Processor(s)
A. Open the Socket Lever
Push the lever handle down
and away from the socket to
release it.
Rotate the lever open all
the way.
B. Open the Load Plate
Push the rear tab with your
finger tip to bring the front
end of the load plate
up slightly.
Open the load plate as shown.
A
B
A
B
F. Close Load Plate and Socket Lever
Close the load plate all the way
as shown.
Close the socket lever and
ensure that the load plate tab
engages under the socket lever
when fully closed.
With your finger, push down
on the load plate as shown.
D. Remove the
Processor
Protective Cover
Take the processor out
of the box and remove
the protective shipping
cover.
E. Install the Processor
Orient the processor with the socket
so that the processor cutouts match
the two socket pins.
A
Install the processor as shown.
A
A
C
A
B
C. Remove Socket Protective Cover
Save the protective cover.
Grasp the socket protective cover
by the two tabs and carefully lift straight
up as shown.
A
A
CAUTION: The underside of the
processor has components that
may damage the socket wires if
installed improperly.
Processor must align correctly with
the socket opening before installation.
DO NOT DROP processor into socket!
A
B
Cautions:
2. When unpacking a processor, hold by the
edges only to avoid touching the gold
contact wires.
1. When opening a socket, DO NOT TOUCH
the gold socket wires.
B
A
C
B
A
1. To avoid damage, DO NOT
DROP the cover onto the
socket wires or components.
Components
CD First
2
Remove Side Cover
1
2
Remove two screws.
Push in latch.
3
Slide side cover
rearward and remove.
2
3
1
1
To avoid integration difficulties and
possible damage to your system,
make sure you have components
from each category below.
6
Install Active Heat Sink(s)
A typical active heat sink is shown below.
Each heatsink has four captive fasteners and should be
tightened as follows:
If a protective film covers the thermal interface material (TIM) on the
underside of the heatsink, remove the protective film.
Using a #2 Phillips* screwdrive r, finger-tighten each
fastener diagonally, according to the white-circled numbers.
Securely re-tighten each fastener again in the same order as
performed in Step C.
D
Attach fan power cable to server board as shown.
E
C
A
Align heatsink fins to the front and back of the chassis for correct airflow.
Airflow goes from front-to-back of chassis.
See airflow diagram at right.
B
2
3
1
4
CAUTION: Do not
over-tighten fasteners.
TIM
Air Flow
Chassis Front
A
C
D
E
Note: Heatsink
styles may vary
Intel
®
Server System SC5650BCDP
Airflow Diagram
LOCK
Airflow
B
Airflow
CAUTION: The heat sink has thermal interface material (TIM)
on the underside of it. Use caution so that you do not damage
the thermal interface material. Use gloves to avoid sharp edges.
3
Remove Front Bezel
Assembly
3
Disengage three bezel clips that attach the right side
of the bezel to the right side of the chassis and remove.
2
Rotate left side of front bezel assembly outward slightly.
1
Lift outward two bezel tabs on left side of bezel
assembly to detach bezel assembly from the chassis.
2
3
1
3
3
1
4
Remove Tool-less Hard Drive Cage
2
2
Push blue plastic
release mechanism
upward to unlatch
hard drive cage.
1
Loosen thumb screw. Apply pressure
to right side of EMI shield to release
EMI shield from hard drive cage.
Once released, pull hard drive
cage out of chassis.
3
1
3
2

Summary of content (1 pages)