Technical Product Specification

Table Of Contents
Intel
®
Server Board S5400SF TPS Server Management
Revision 2.02
Intel order number: D92944-007
49
Beep code generation: The Integrated BMC generates diagnostic beep codes for fault
conditions.
Hot-swap backplane support: The Integrated BMC pushes the power supply state to the
hot-swap controller.
System GUID storage and retrieval.
Memory RAS: The Integrated BMC provides sensors to track the DIMM state and
memory RAS redundancy state. The Integrated BMC provides IPMI OEM commands to
enable the BIOS to push this information to the Integrated BMC.
Front panel management: The Integrated BMC controls system fault and chassis ID
LEDs. It supports secure lockout of certain front panel functionality. It monitors button
presses. The chassis ID can be turned on from a front panel button or through a
command.
Power unit management: The Integrated BMC supports a power unit sensor. The
Integrated BMC handles power-good dropout condition.
NMI: The Integrated BMC provides commands to set/get the NMI source. It supports the
generation of an NMI signal due to a watchdog timer, IPMI command, or front panel NMI
button. The Integrated BMC monitors the system NMI signal.
ARPs: The Integrated BMC can send and respond to an ARP. This is supported on
Intel
®
6321ESB I/O Controller Hub embedded NICs.
DHCP: The Integrated BMC supports DHCP on Intel
®
6321ESB I/O Controller Hub
embedded NICs.
SMTP: The Integrated BMC supports SMTP on Intel
®
6321ESB I/O Controller Hub
embedded NICs.
Integrated BMC timeclock sync with SIO RTC: At Integrated BMC startup, the Integrated
BMC reads SIO RTC and updates its internal time clock to match. The Integrated BMC
updates SIO RTC if Integrated BMC internal timeclock is updated by Set SEL Time IPMI
command.
Chassis intrusion fan interactions: Fans go to high speed when the chassis intrusion
signal is asserted. This is available only on systems that have chassis intrusion support.
4.1.3 New Features
This section lists features that are being introduced on Intel
®
Server Boards and systems that
use the Intel
®
5400 Chipset:
Acoustic management: Improved acoustic levels are achieved by including support for
CLTT and fan profiles using TControl version 2 SDRs.
Intel
®
Remote Management Module 2 (Intel
®
RMM 2) support: The Integrated BMC
supports the Intel
®
Remote Management Module 2 as an add-in card. This card utilizes
its own ASMI NIC to provide advanced server management features that work in
conjunction with the Integrated BMC. This support includes the following:
- IPMI and IPMI OEM commands to support discovery and configuration of the
Integrated BMC by Intel
®
RMM2.
- Integrated BMC usage of ASMI NIC via FML (FML used as an extra NIC channel to
the Integrated BMC). Integrated BMC can support IPMI over LAN and SOL using this
interface.
- Integrated BMC forwarding of event log messages to Intel
®
RMM2.