After successful completion of the firmware update process, the firmware update
utility may generate an error stating that the Integrated BMC is still in update mode.
5. Power down and remove AC power.
6. Open the server and move the jumper from the “enabled” position (pins 2-3) to the
“disabled” position (pins 1-2).
7. Close the server system and reconnect AC power and power up the server.
Note: Normal Integrated BMC functionality is disabled with the Integrated BMC force update
jumper set to the “enabled” position. The server should never be run with the Integrated BMC
force update jumper set in this position and should only be used when the standard firmware
update process fails. This jumper should remain in the default disabled position when the server
is running normally.
7.2 BIOS Select Jumper
The jumper block at J3H1, located just to the left of the SSI control panel header, is used to
select the BIOS image to which the system boots. Pin 1 on the jumper is identified with a ‘’.
This jumper should only be moved if you wish to force the BIOS to boot to the secondary bank,
which may hold a different version of the BIOS.
The rolling BIOS feature of the server board automatically alternates the boot BIOS to the
secondary bank in the event the BIOS image in the primary bank is corrupted and cannot boot
for any reason.