Technical Product Specification

Table Of Contents
Intel
®
Server Board S5400SF TPS Connector/Header Locations and Pin-outs
Revision 2.02
Intel order number: D92944-007
129
6.7.5 SATA Connectors
The server board provides six Serial ATA (SATA) connectors: SATA-0 (J1H1), SATA-1 (J1G2),
SATA-2 (J1G1), SATA-3 (J1F2), SATA-4 (J1F1), and SATA-5 (J1E2), for use with an internal
SATA backplane. The pin configuration for each connector is identical and is defined in the
following table.
Table 72. SATA Connector Pin-out (J1H1, J1G2, J1G1, J1F2, J1F1, J1E2)
Pin Signal Name Description
1 GND Ground
2 SATA#_TX_P_C Positive side of transmit differential pair
3 SATA#_TX_N_C Negative side of transmit differential pair
4 GND Ground
5 SATA#_RX_N_C Negative side of Receive differential pair
6 SATA#_RX_P_C Positive side of Receive differential pair
7 GND Ground
6.7.6 Serial Port Connectors
The server board provides one external RJ-45 Serial ‘B’ port (J9A2) and one internal 9-pin
Serial ‘A’ port header (J1B1). The following tables define the pin-outs for each.
Table 73. External RJ-45 Serial ‘B’ Port Pin-out (J9A2)
Pin Signal Name Description
1 SPB_RTS RTS (request to send)
2 SPB_DTR DTR (Data terminal ready)
3 SPB_OUT_N TXD (Transmit data)
4 GND Ground
5 SPB_RI RI (Ring Indicate)
6 SPB_SIN_N RXD (receive data)
7 SPB_DSR _DCD Data Set Ready/Data Carrier Detect
1
8 SPB_CTS CTS (clear to send)
Note: A jumper block on the server board determines whether DSR or DCD is routed to pin 7. The
board has the jumper block configured with DSR enabled at production.
Table 74. Internal 9-pin Serial ‘A’ Header Pin-out (J1B1)
Pin Signal Name Description
1 SPA_DCD DCD (carrier detect)
2 SPA_DSR DSR (data set ready)
3 SPA_SIN_L RXD (receive data)
4 SPA_RTS RTS (request to send)
5 SPA_SOUT_N TXD (Transmit data)
6 SPA_CTS CTS (clear to send)
7 SPA_DTR DTR (Data terminal ready)
8 SPA_RI RI (Ring Indicate)
9 GND Ground