Intel® Server System SR1560SF Service Guide A Guide for Technically Qualified Assemblers of Intel® Identified Subassemblies/ Products Intel Order Number D92960-004
Disclaimer Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document.
Intel® Server System SR1560SF Service Guide iii
iv Intel® Server System SR1560SF Service Guide
Preface About this Manual Thank you for purchasing and using the Intel® Server System SR1560SF. This manual is written for system technicians who are responsible for troubleshooting, upgrading, and repairing this server system. This document provides reference information, feature information, and step by step instructions on how to add and replace components on the server system. For the latest version of this manual, see http://support.intel.com/support/motherboards/server/s5400sf.
Product Contents The Intel® Server System SR1560SF ships with the Intel® Server Board S5400SF. For further information, see the following documents: • Intel® Server Board S5400SF Technical Product Specification • Intel® Server System SR1560SF Technical Product Specification There are two versions of the Intel® Server System SR1560SF: product codes SR1560SF and SR1560SFHS. The contents of each server system are listed below.
Intel® Server System SR1560SF - Product Code SR1560SFHS Contents Your Intel® Server System SR1560SF ships with the following items: • • • • • • • Intel® Server Board S5400SF, installed in the server system One 600 W power supply, installed in the server system A box of hardware components, referred to below as the "hardware box" PCIe* riser card assembly, installed in the server system Optical drive tray assembly (tray and interposer board), in the hardware box Bridge board, in the hardware box Optical dr
viii Intel® Server System SR1560SF Service Guide
Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Intel® Server Deployment Toolkit 2.0 CD and/or at http://support.intel.com/support/motherboards/server/sb/cs-010770.htm. Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen.
重要安全指导 在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。 和/或 http://support.intel.com/support/motherboards/server/sb/CS-010770.
Warnings Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide.
xii Intel® Server System SR1560SF Service Guide
Table of Contents Preface ......................................................................................................................... v About this Manual .................................................................................................................. v Manual Organization .............................................................................................................. v Product Contents .............................................................................
Removing the Processor Air Duct ............................................................................... 24 Installing the Processor Air Duct ................................................................................. 24 Installing and Removing Memory ........................................................................................ 25 Installing DIMMs .......................................................................................................... 27 Removing DIMMs .............
Replacing the Power Supply ................................................................................................51 Replacing the Control Panel Module (Hot-swap Drive System) ..........................................52 Replacing the Control Panel Module (Fixed Drive System) .................................................54 Replacing a System Fan ......................................................................................................55 Installing and Removing the Rack Handles .....
Appendix F: Warranty ...............................................................................................93 Limited Warranty for Intel® Chassis Subassembly Products .............................................. 93 Appendix G: Installation/Assembly Safety Instructions .......................................97 English ................................................................................................................................. 97 Deutsch ........................................
Autres risques ............................................................................................................124 Périphériques laser ....................................................................................................125 Español ..............................................................................................................................125 Información de seguridad del servidor ......................................................................
xviii Intel® Server System SR1560SF Service Guide
List of Figures Figure 1. Intel® Server System SR1560SF ............................................................................... 3 Figure 2. Cable Routing for Hot-Swap Drive System ................................................................ 6 Figure 3. Cable Routing for Fixed Drive System ....................................................................... 7 Figure 4. System Components..................................................................................................
Figure 42. Installing a Full Height Add-In Card ....................................................................... 40 Figure 43. Removing a Full Height Add-In Card ..................................................................... 40 Figure 44. Installing the I/O Expansion Module to the Server Board ...................................... 41 Figure 45. Removing the I/O Expansion Module(s) from the Server Board............................ 41 Figure 46.
List of Tables Table 1. Server System References ......................................................................................... 1 Table 2. Intel® Server System SR1560SF Feature Summary ................................................... 4 Table 3. NIC LED Descriptions ...............................................................................................13 Table 4. Setup Menu Key Use ................................................................................................
xxii Intel® Server System SR1560SF Service Guide
1 Server System References If you need more information about this product or information about the accessories that can be used with this server system, use the following resources. Table 1. Server System References For this information or software For in-depth technical information about the server system, including sub-system overviews and mechanical drawings Use this Document or Software Intel® Server System SR1560SF Technical Product Specification Found at: http://support.intel.
Table 1. Server System References For this information or software Use this Document or Software Hardware (peripheral boards, adapter cards) and operating systems that have been tested with this product Tested Hardware Operating Systems List To make sure your system falls within the allowed power budget Power Budget Tool Found at: http://support.intel.com/support/motherboards/server/S5400SF/ Found at: http://support.intel.
2 Server System Features This chapter briefly describes the main features of the server system. This chapter provides illustrations of the product, a list of the server system features, and diagrams showing the location of important components and connections on the server system. AF002374 Figure 1.
Table 2 summarizes the features of the server system. Table 2. Intel® Server System SR1560SF Feature Summary Feature Dimensions Description • • • • 1.703 inches (43.25 mm) high 16.930 inches (430 mm) wide 27.25 inches (692 mm) deep 31 pounds (14.1 kg) - max chassis weight Server Board Intel® Server Board S5400SF Processor Support for up to two Multi-Core Intel® Xeon® processors 5000 sequence. For a complete list of supported processors, see: http://support.intel.
Table 2.
Cable Routing (Hot-Swap Drive System) When you add or remove components from your server system, make sure your cables are routed correctly before reinstalling the server system cover. Use caution to make sure no cables or wires are pinched and that the airflow from the fans is not blocked. Use the figures below to determine the correct cable routing for a hot-swap drive system.
Cable Routing (Fixed Drive System) When you add or remove components from your server system, make sure your cables are routed correctly before reinstalling the server system cover. Use caution to make sure no cables or wires are pinched and that the airflow from the fans is not blocked. Use the figures below to determine the correct cable routing for a fixed drive system.
Chassis Component Identification This section helps you identify the components of your server system. If you are near the system, you can also use the Quick Reference Label provided on the inside of the chassis cover to assist in identifying components. Internal Components D E C F G B A M L H K I J A AF002186 A. Rack handles H. Fan module B. Air baffle I. Fan board (fixed drive system) or backplane (hot-swap drive system) C. Power supply J. Control panel D. Server board K.
Server Board Connector and Component Locations A B C D E F G II HH GG FF EE DD CC BB AA Z H I Y X W V U J T K S R Q PO NM L AF002159 A. Intel® RMM2 NIC Connector B. IO Module Option Connector C. POST Code Diagnostic LEDs D. PCI Express* Riser Connector (x16 Gen2) E. System Identification LED - Blue F. Status LED - Green / Amber G. External IO Connectors H. FBDIMM Memory Sockets I. Serial 'B' Port Configuration Jumper J. Processor 1 Socket K. Processor 2 Socket L.
Configuration Jumpers BIOS Select J3H1 1-2: Force Lower Bank 3 2-3: Normal Operation (Default) 3 AF002171 Jumper Name BIOS Select Jumper Purpose If pins 1-2 are jumpered, the BIOS in the lower bank will be selected on the next reset. These pins should be jumpered on 2-3 for normal operation. Figure 6.
BMC Force Update Mode Disable Password Reset 2 2 3 3 Enable 2 CMOS Clear 3 AF002170 Jumper Name Jumper Purpose CMOS Clear If pins 2-3 are jumpered, the CMOS settings will be cleared on the next reset. These pins should be jumpered on 1-2 for normal operation. See “Clearing the CMOS” on page -62for complete CMOS clear instructions. Password Clear If pins 2-3 are jumpered, administrator and user passwords will be cleared on the next reset.
Intel® Light Guided Diagnostics The server board contains numerous LEDs providing the following functions: • Fault LEDs help identify failed and failing components. The fault LEDs turn on (amber) if there is a memory or processor fault. • The System Status LED that shows the over all health of the system (green, blinking green, blinking amber, amber). • POST Code Diagnostic LEDs change color or state (off, green, red, amber) according to the POST sequence.
Back Panel Connectors A G B C D E F H AF002161 A. Mouse B. Keyboard C. Serial Port B (RJ45) D. NIC 1 (10/100/1000 Mb) E. NIC 2 (10/100/1000 Mb) F. Video G. USB Port 6 H. USB Port 5 Figure 9. Back Panel Connectors The NIC LEDs at the right and left of each NIC provide the following information. Table 3.
SAS/SATA Backplanes The hot-swap drive system can support either an active SAS backplane (Product Code ASR1500SASBP) or a passive SAS/SATA backplane (Product Code - ASR1500PASBP). The backplanes provide the platform support for peripheral drives and hot-swap SAS or SATA hard drives. To eliminate several cables, the backplanes are also used as a pathway for signals from the server board to various platform interconnects, including those for the control panel and peripheral drives.
RAID Support The Intel® Server System SR1560SF (product code SR1560SF) provides an embedded SATA controller that supports both 1.5 and 3.0 Gbps data transfer rates. The Intel® Server System SR1560SF (product code SR1560SFHS) provides SAS and SATA support. Both systems can be configured for RAID 0, 1, and 10. The Intel® Server System SR1560SF can be configured for SW RAID 5 by using the Intel® RAID Activation Key AXXRAKSW5 accessory.
Callout E. Feature Function Hard Disk Drive Activity LED Random blinking green light indicates hard disk drive activity (SAS or SATA). No light indicates no hard disk drive activity. F. System Status LED Solid green indicates normal operation. Blinking green indicates degraded performance. Solid amber indicates a critical or non-recoverable condition. Blinking amber indicates a non-critical condition. No light indicates POST is running or the system is off. G.
Rear of Server System A L B K J I H G F E C D AF002187 A. PS2 mouse connector G. USB 5 connector B. PCI card bracket (full height) H. Video connector C. AC Power Receptacle I. NIC 2 connector D. Management Network Interface (optional) J. NIC 1 connector E. IO module external connector (optional) K. RJ45 serial B port F. USB 6 connector L. PS2 keyboard connector Figure 12.
Peripheral Devices The server system provides locations and hardware for installing hard drives, a USB floppy drive, and an optical drive. The drives must be purchased separately. The following figure shows the available options. A B D C AF002191 . A. Slimline drive bay (drive not included) B. Control panel C. Hard drive status LEDs (hot-swap drives only) D. Hard drive bays (drives not included) Figure 13.
Note: For a list of supported hard drives, see the Tested Hard Drive List at http:// support.intel.com/support/motherboards/server/s5400sf/compat.htm. Slimline Optical Drive Carrier The slimline optical drive carrier is used when installing an optional optical drive. One slimline carrier is included with your server system; the optical drive must be purchased separately. The slimline optical drive carrier can only be inserted or removed when the system power is turned off.
20 Intel® Server System SR1560SF Service Guide
3 Hardware Installations and Upgrades Before You Begin Before working with your server product, pay close attention to the “Safety Information” at the beginning of this manual. Note: Whenever you service the system, you must first power down the server and unplug all peripheral devices and the AC power cord.
Removing the Front Bezel Unlock the bezel and pull the bezel from the server system. AF002373 Figure 14. Removing the Front Bezel Installing the Front Bezel At each end of the bezel, line up the center notch on the bezel with the center guide on the rack handles and push the bezel onto the front of the server system until it clicks into place. AF002372 Figure 15.
Note: A nonskid surface or a stop behind the server system may be needed to prevent the server system from sliding on your work surface. 1. Remove the top cover screw (see letter “A”). 2. Slide the cover back until it stops and lift the cover upward to remove it (see letter “B”). B A AF002371 Figure 16. Removing the Server System Cover Installing the System Cover Place the cover over the server system so that the side edges of the cover sit just inside the server system sidewalls. 1.
Removing and Installing the Processor Air Duct Always operate your server system with the processor air duct in place. The air duct is required for proper airflow within the server system. Removing the Processor Air Duct Lift the processor air duct from its location over the two processor sockets. AF002362 Figure 18. Removing the Processor Air Duct Installing the Processor Air Duct Turn processor air duct over to reveal underside.
Place the processor air duct over the processor sockets. The front edge of the air duct should contact the fan module. Use caution not to pinch or disengage cables that may be near or under the air duct. AF002363 Figure 20.
DIMM D1 DIMM D2 DIMM D3 DIMM D4 DIMM B1 DIMM B2 DIMM B3 DIMM B4 DIMM C1 DIMM C2 DIMM C3 DIMM C4 DIMM A4 DIMM A3 DIMM A2 DIMM A1 Channel A Channel B Branch 0 Channel C Channel D Branch 1 AF002164 Figure 21. Installing the Initial Four DIMMs Notes: The initial four DIMMs installed must be populated in the blue slots: DIMM A1, DIMM B1, DIMM C1, and DIMM D1.
Installing DIMMs 1. Make sure the clips at either end of the DIMM socket(s) are pushed outward to the open position (see letter “A”). 2. Holding the DIMM by the edges, remove it from its anti-static package and position the DIMM above the socket. Align the notch on the bottom edge of the DIMM with the key in the DIMM socket. The arrow in the inset in Figure 22 is pointing to the key in the socket (see letter “B”). 3. Insert the bottom edge of the DIMM into the socket (see letter “C”). 4.
Installing the Processor 1. Locate the processor socket and raise the socket handle completely (see Figure 23). TP02074 Figure 23. Lifting the Processor Socket Handle 2. Raise the CPU load plate (see Figure 24). A B TP02075 Figure 24. Installing the Processor Note: Do not touch the socket pins; they are very sensitive and easily damaged.
3. Line up the alignment marks on the processor and the socket, and insert the processor into the socket. A B TP02084 Note: Make sure the alignment triangle mark and the alignment triangle cutout align correctly. 4. Remove the protective socket cover (see Figure 25). Caution: Protective socket cover needs to be removed for proper cooling of the processor; failure to remove the cover could result in damage to the system.
3. Gradually and equally tighten each captive screw until each is firmly tightened. 2 3 4 1 AF002386 Figure 26. Installing the Heat Sink (1U Passive Heat Sink Shown) Removing a Processor 1. Loosen the four captive screws on the corners of the heat sink. 2. Twist the heat sink slightly to break the seal between the heat sink and the processor. 3. Lift the heat sink from the processor. If it does not pull up easily, twist the heat sink again. Do not force the heat sink from the processor.
Always operate your server system with the small air baffle in place. The small air baffle is required for proper airflow within the server system. Removing the Small Air Baffle Pull up on the air baffle to remove it. AF002364 Figure 27. Removing the Small Air Baffle Installing the Small Air Baffle Lower the baffle into the server system and position baffle over the two stand-off locations. Press into place as shown in the figure below. AF002365 Figure 28.
Installing and Removing a Hot-swap Hard Drive Up to three hot-swap SAS or SATA drives can be installed in the Intel® Server System SR1560SF - product code SR1560SFHS. Cautions: If you install less than three drives or devices, the empty drive bays must be occupied by carriers with drive blanks to maintain proper system cooling. To avoid possible damage to your server system, use only the drive carriers that came with your system.
4. Remove the hard drive from its wrapper and place it on an antistatic surface. 5. Set any jumpers and/or switches on the drive according to the drive manufacturer's instructions. 6. With the drive circuit-side down, position the connector end of the drive so that it is facing the rear of the drive carrier. 7. Align the holes in the drive to the holes in the drive carrier and attach it to the carrier with the screws that were attached to the drive blank. B A B TP02208 Figure 31.
3. If you are not installing a new drive, place the drive blank into the drive carrier, using the four screws you removed from the hard drive. 4. With the black lever in the fully open position, slide the drive carrier into the server system. The green latch must be to the right. Do not push on the black lever until the lever begins to close by itself. Note: All hard drive carriers must be installed in the server system and populated with either a drive or a drive blank to maintain system thermals. 5.
3. Install the hard drive into the hard drive carrier using four screws (see the figure below). AF002381 Figure 34. Installing Fixed Hard Drive into the Carrier 4. Install the hard drive carrier into the server system until it clicks into place. Note: All hard drive carriers must be installed in the server system and populated with either a drive or a drive blank to maintain system thermals. 5. Connect power to hard drive(s). 6. Connect SATA cables between the hard drive(s) and the server board.
4. If replacing the hard drive, install the replacement drive using the four screws you just removed. For instructions, see “Installing a Fixed Hard Disk Drive”. 5. If the hard drive will not be replaced, install a drive blank into the carrier using the four screws you just removed. 6. Install the hard drive carrier into the server system until it clicks into place. Installing or Removing a Slimline Optical Drive Cautions: Slimline optical drives are NOT hot-swappable.
6. Insert the optical drive tray assembly into the server system as shown in the figure below. AF000355 Figure 37. Installing an Optical Drive Assembly into the Server System 7. Verify that the blue release lever on the tray locks into place. 8. Obtain the cable from the hardware box and install the cable to the interposer board and the server board. Removing a Slimline Optical Drive 1.
2. Press downward on the side of the tray (see letter “A”) and disengage the drive from the two metal tabs on the opposite side of the tray. 3. Slide the optical drive out (see letter “B”) and lift up (see letter “C”) to remove it from the tray. C B A AF000152 Figure 39. Removing the Slimline Optical Drive from the Tray Filling Empty Server System Bays A filler panel or drive blank must be installed into an empty drive bay. To access the drive bays, remove the front bezel if it is installed.
AF002354 Figure 40. Removing PCI Riser Assembly from the Server System Installing the PCI Riser Assembly 1. Lower the riser assembly into place (see letter “A”). 2. Align the two hooks in the riser assembly with the matching slots at the back of the server system (see letter “B”). A B AF002355 Figure 41. Installing PCI Riser Assembly into the Server System 3. Press down uniformly until the two hooks on the rear of the PCI riser assembly engage the server system back panel slots.
4. Connect any cables to add-in cards that require them. See your add-in card documentation for information and add-in card requirements. Installing and Removing a PCI Add-in Card The instructions below describe how to install and remove a PCI add-in card. Installing a PCI Add-in Card 1. Remove the filler panel from the add-in card slot. 2. Insert add-in card until it seats in riser card connector (see letter “A”). 3. Screw the add-in card in place (see letter “B”). B A AF002367 Figure 42.
Installing and Removing the I/O Expansion Module(s) Installing the I/O Expansion Module(s) 1. Squeeze the sides of the I/O expansion module cover to disengage it from the server system back panel and remove it (see letter “A”). 2. Attach the standoffs to the server board (see letter “B”) and attach the I/O expansion module(s) to the server board (see letter “C”). I/O Expansion Module (Dual Gigabit) I/O Expansion Module (External SAS) B C A AF002376 Figure 44.
Installing and Removing the Intel® Remote Management Module 2 and the Intel® RMM 2 NIC Installing the Intel® RMM2 and Intel® RMM2 NIC 1. Squeeze the sides of the Intel® RMM2 NIC module cover to disengage it from the server system back panel and remove it. 2. Attach the foam gasket to the bottom of the Intel® RMM2 NIC module (see letter “A”). Note: The Intel® RMM2 NIC module is shown upside down in the first illustration below in order to provide better detail on installing the foam gasket. 3.
Removing the Intel® RMM2 and Intel® RMM2 NIC 1. Remove the Intel® RMM2 board (see letter “A”) and standoffs (see letter “B”) from the server board . 2. Remove the Intel® RMM2 NIC module (see letter “C”) and standoffs (see letter “D”) from the server board. 3. Install the Intel® RMM2 NIC module cover into the system back panel. A C B D AF002379 Figure 47.
D A B C AF002348 Figure 48. Installing the Backplane into the Server System 4. Connect fan, USB, and front panel cables as necessary to the backplane board. 5. Install the bridge board by opening the retention mechanism (see letter “A”) and inserting it into the connector on the server board (see letter “B”). Close the retention mechanism to hold the bridge board in place. B A C A C AF000372 Figure 49.
Removing the Backplane Board 1. Disengage hard drives from the backplane board. 1. Disconnect all cables from the backplane board. 2. Remove the bridge board by lifting the retention mechanism from the backplane and the server board (see letter “A”), and lifting straight up (see letter “B”). .. B B A A AF000373 Figure 50. Removing the Bridge Board from the Server System 3. Disconnect the power from the backplane board (see letter “A”). 4.
Figure 51. Removing the Backplane from the Server System 7. Install a replacement backplane. For instructions, see “Installing the Backplane Board”. 8. Install the bridge board (see Figure 49). Replacing the Fan Board (Fixed Drive System Only) The instructions below describe how to replace the fan board. Removing the Fan Board 1. Disconnect all fan cables from the fan board. 2. Disconnect the power from the fan board (see letter “A”). 3. Remove the screw from the fan board (see letter “B”). 4.
Installing the Fan Board 1. Lower the fan board into the system (see letter “A”) and position the fan board over the retention pins as shown. 2. Slide the fan board to the left (see letter “B”) to lock it in place and install the screw (see letter “C”). 3. Connect power to the fan board power connector (see letter “D”). D C B A AF002350 Figure 53. Installing the Fan Board into the Server System 4. Connect fan cables to the fan board. Replacing the Server Board Removing the Server Board 1.
6. Remove the system fan assembly. 7. Disconnect all power cables coming from the power supply to the server board. 8. Remove the seven screws from the server board (see letter “A”) and lift the server board from the server system (see letter “B”). A B AF002346 Figure 54. Removing the Server Board 9. Install the replacement server board. For instructions, see “Installing the Server Board”.
Installing the Server Board 1. Place the server board into the server system as shown in the figure below (see letter “A”). 2. Attach the server board with seven screws (see letter “B”). B A AF002347 Figure 55. Installing the Server Board 3. Re-connect all power cables coming from the power supply to the server board. 4. Install the system fan assembly. 5. Re-connect all SATA cables to the server board. 6. Install the PCI riser assembly. 7. Install the bridge board (hot-swap systems only). 8.
Replacing the Backup Battery The lithium battery on the server board powers the RTC for up to 10 years in the absence of power. When the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM in the RTC (for example, the date and time) may be wrong. Contact your customer service representative or dealer for a list of approved devices. Warning: Danger of explosion if battery is incorrectly replaced.
1. Locate the battery and insert the tip of a small flat bladed screwdriver, or an equivalent, under the tab in the plastic retainer. Gently push down on the screwdriver to lift the battery. 2. Remove the battery from its socket. AF002375 Figure 56. Replacing the Backup Battery 3. Dispose of the battery according to local ordinance. 4. Remove the new lithium battery from its package, and, being careful to observe the correct polarity, insert it in the battery socket.
The power supply can be replaced if it fails or if one of the fans that is integrated into it fails. To replace the power supply, use the following instructions. 1. Disconnect all power cables. 2. Lift the power supply to disengage it from the latch (see letter “A”) and remove the power supply by sliding it out (see letter “B”). B A supply, re-connect all power cables in step 1 above, and reconnect AC power cord. AF002358 Figure 57. Removing Power Supply from the Server System 3.
1. Unplug the front panel and USB cables from the backplane (see letters “A” and “B”). 2. Press the latch at the back of the control panel (see letter “C”). 3. Slide the control panel out through the front of the server system (see letter “D”). A C B D AF002342 Figure 59. Removing the Control Panel Module (Hot-swap Drive System) 4. Slide the replacement control panel into the server system (see letter “A”) until it clicks into place. 5.
Replacing the Control Panel Module (Fixed Drive System) Your server must be operated with a control panel installed. Caution: The control panel is NOT hot-swappable. Before removing or replacing the control panel, you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pressing the power button, and unplug the AC power cord from the system or wall outlet. 1. Unplug the USB cable from the server board (see letter “A”). 2.
6. Slide the replacement control panel into the server system (see letter “A”) until it clicks into place. 7. Route the USB and front panel cables through the retaining clip on the fan board (see letter “B”). 8. Connect the front panel cable to the connector on the server board (see letter “C”). 9. Connect the USB cable to the connector on the server board (see letter “D”). D B A C AF002345 Figure 62.
1. Disconnect the fan cable from the backplane or fan board (see letter “A”). Lift the failed fan from the module (see letter “B”). A B AF002356 Figure 63. Removing a Fan from the Fan Module 2. Position the replacement fan so the connector on the fan is at the right and pointing down. 3. With the fan oriented correctly, insert the fan into the fan module (see letter “A”), and insert the fan cable into the matching connector on the backplane or fan board (see letter “B”). B A AF002357 Figure 64.
Installing and Removing the Rack Handles Installing the Rack Handles Align the rack handle with the two holes on the side of the server system and attach the rack handle with the two screws. AF000377 Figure 65. Installing the Rack Handle Removing the Rack Handles Remove the two screws holding the rack handle in place, and remove the rack handle from the server system. AF000378 Figure 66.
58 Intel® Server System SR1560SF Service Guide
4 Server Utilities Using the BIOS Setup Utility This section describes the BIOS Setup Utility options, which is used to change server configuration defaults. You can run BIOS Setup with or without an operating system being present. See “Server System References” for a link to the Intel® Server Board S5400SF Technical Product Specification where you will find details about specific BIOS setup screens.
“Setup Menu Key Use” describes the keyboard commands you can use in the BIOS Setup menus. Table 4. Setup Menu Key Use Key to Press Description Pressing on any menu invokes the general help window. Left and right arrows The left and right arrow keys are used to move between the major menu pages. The keys have no affect if a submenu or pick list is displayed. Up arrow Select Item up - The up arrow is used to select the previous value in a menu item's option list, or a value field pick list.
Table 4. Setup Menu Key Use Key to Press Description Save and Exit - Pressing causes the following message to appear: Setup Confirmation Save Configuration changes and exit now? [Yes] [No] If "Yes" is selected and the key is pressed, all changes are saved and Setup is exited. If "No" is selected and the key is pressed, or the key is pressed, the user is returned to where they were before was pressed without affecting any existing values.
Obtaining the Upgrade Download the BIOS image file to a temporary folder on your hard drive. See “Server System References” for a link to the update software. Note: Review the instructions and release notes that are provided in the readme file distributed with the BIOS image file before attempting a BIOS upgrade. The release notes contain critical information regarding jumper settings, specific fixes, or other information to complete the upgrade.
4. Wait five seconds. 5. Return the CMOS Clear jumper to the CMOS Protect location, covering pins 1 and 2. 6. Close the server chassis. 7. Power up the system. 8. The CMOS is now cleared and can be reset by going into the BIOS setup. Resetting the Password If the user or administrator password(s) is lost or forgotten, moving the password reset jumper into the "clear" position clears both passwords. The password reset jumper must be restored to its original position before a new password(s) can be set. 1.
64 Intel® Server System SR1560SF Service Guide
Appendix A: Technical Reference 600W Single Power Supply Input Voltages • 100-127V at 50/60 Hz; 8.55 A max. • 200-240V at 50/60 Hz; 4.3 A max. System Environmental Specifications Table 5. System Environmental Specifications Temperature Non-operating -40 ° to +70 °C. Operating 10° C to 35° C (50° F to 90° F) with the maximum rate of change not to exceed 10° C per hour Humidity Non-operating 90% relative humidity (non-condensing) at 28 °C. Shock Operating 2.
66 Intel® Server System SR1560SF Service Guide
Appendix B: Intel® Server Issue Report Form Note: An on-line / automatic submission version of this form is available at http:// support.intel.com/support/motherboards/server/s5400sf/. For the fastest service, please submit your form via the Internet.
DIMM Configuration DIMM A1 MB and Vendor / part number: __________________________________ DIMM A2 MB and Vendor / part number: __________________________________ DIMM A3 MB and Vendor / part number: __________________________________ DIMM A4 MB and Vendor / part number: __________________________________ DIMM B1 MB and Vendor / part number: __________________________________ DIMM B2 MB and Vendor / part number: __________________________________ DIMM B3 MB and Vendor / part number: ________________________
Add-in Card, Peripheral, Video, NIC Check each box below as applicable, and provide the requested information.
Complete Problem Description In the space below, provide a complete description of the steps used to reproduce the problem or a complete description of where the problem can be found. Please also include any details on troubleshooting already done.
Appendix C: LED Decoder During the system boot process, BIOS executes a number of platform configuration processes, each of which is assigned a specific hex POST code number. As each configuration routine is started, BIOS will display the given POST code to the POST Code Diagnostic LEDs found on the back edge of the server board. To assist in troubleshooting a system hang during the POST process, the Diagnostic LEDs can be used to identify the last POST process to be executed.
Table 7.
Table 7.
Table 7.
Table 7.
Table 7. Diagnostic LED POST Code Decoder 76 0x31h OFF OFF R A Crisis recovery has been initiated by software (corrupt flash) 0x34h OFF G R R Loading crisis recovery capsule 0x35h OFF G R A Handing off control to the crisis recovery capsule 0x3Fh G G A A Unable to complete crisis recovery.
Appendix D: Getting Help World Wide Web http://support.intel.com/support/motherboards/server/s5400sf/. Telephone All calls are billed per incident, levied in local currency at the applicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without notice). Before calling, fill out an “Intel® Server Issue Report Form”. A sample form is provided on the following pages.
In Asia-Pacific region Australia.... 1800 649931 Cambodia.. 63 2 636 9797 (via Philippines) China ......... 800 820 1100 (toll-free) .................... 8 621 33104691 (not toll-free) Hong Kong 852 2 844 4456 India........... 0006517 2 68303634 (manual toll-free. You need an IDD-equipped telephone) Indonesia ... 803 65 7249 Korea ......... 822 767 2595 Malaysia .... 1 800 80 1390 Myanmar... 63 2 636 9796 (via Philippines) New Zealand 0800 444 365 Pakistan.....
Colombia ... Contact AT&T USA at 01 800 911 0010. Once connected, dial 800 843 4481 Costa Rica . Contact AT&T USA at 0 800 0 114 114. Once connected, dial 800 843 4481 Ecuador (Andimate) .... Contact AT&T USA at 1 999 119. Once connected, dial 800 843 4481 (Pacifictel) ..... Contact AT&T USA at 1 800 225 528. Once connected, dial 800 843 4481 Guatemala. Contact AT&T USA at 99 99 190. Once connected, dial 800 843 4481 Mexico ....... Contact AT&T USA at 001 800 462 628 4240.
80 Intel® Server System SR1560SF Service Guide
Appendix E: Regulatory and Compliance Information Product Regulatory Compliance Warning: To ensure regulatory compliance, you must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide.
Product Regulatory Compliance References The following table references Server Chassis Compliance and markings that may appear on the product. Markings below are typical markings however, may vary or be different based on how certification is obtained. Note: Certifications Emissions requirements are to Class A. Table 8.
Table 8.
Table 8.
Electromagnetic Compatibility Notices FCC Verification Statement (USA) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. For questions related to the EMC performance of this product, contact: Intel Corporation 5200 N.E.
Industry Canada (ICES-003) Cet appareil numérique respecte les limites bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur: "Apparelis Numériques", NMB-003 édictee par le Ministre Canadian des Communications.
Korean Compliance (RRL) Following is the RRL certification information for Korea. English translation of the notice above: 1. Type of Equipment (Model Name): On License and Product 2. Certification No.: On RRL certificate. Obtain certificate from local Intel representative 3. Name of Certification Recipient: Intel Corporation 4. Date of Manufacturer: Refer to date code on product 5.
Table 9. Product Ecology Compliance Markings Compliance Regional Description California China Compliance Reference California Code of Regulations, Title 22, Division 4.5; Chapter 33: Best Management Practices for Perchlorate Materials. Compliance Reference Marking Example Special handling may apply. See www.dtsc.ca.gov/ hazardouswaste/perchlorate. This notice is required by California Code of Regulations, Title 22, Division 4.5; Chapter 33: Best Management Practices for Perchlorate Materials.
Compliance Regional Description Europe Compliance Reference European Directive 2002/95/EC - Compliance Reference Marking Example None Required. Restriction of Hazardous Substances (RoHS). Threshold limits and banned substances are noted below. Quantity limit of 0.1% by mass (1000 PPM) for: Lead, Mercury, Hexavalent Chromium, Polybrominated Biphenyls Diphenyl Ethers (PBB/PBDE) Quantity limit of 0.
Other Markings Table 10. Other Markings Compliance Description Compliance Reference Compliance Reference Marking Example Stand-by Power Stand-by Power Warnings Multiple Power Cords Multiple Power Cords Warnings English: Applied to product if more than one power cord is used. This unit has more than one power supply cord. To reduce the risk of electrical shock, disconnect (2) two power supply cords before servicing. Applied to product if stand-by power switch is used.
Compliance Description Ground Connection Compliance Reference Ground Connection Warnings Compliance Reference Marking Example Line1 : “WARNING:” Swedish on line2: “Apparaten skall anslutas till jordat uttag, när den ansluts till ett nätverk." Finnish on line 3: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan." English on line 4: "Connect only to a properly earth grounded outlet.
End-of-Life / Product Recycling Product recycling and end-of-life take-back systems and requirements vary by country. Contact the retailer or distributor of this product for information about product recycling and / or take-back.
Appendix F: Warranty Limited Warranty for Intel® Chassis Subassembly Products Intel warrants that the Products (defined herein as the Intel® chassis subassembly and all of its various components and software delivered with or as part of the Products) to be delivered hereunder, if properly used and installed, will be free from defects in material and workmanship and will substantially conform to Intel's publicly available specifications for a period of three (3) years after the date the Product was purchased
This Limited Warranty does not cover damages due to external causes, including accident, problems with electrical power, usage not in accordance with product instructions, misuse, neglect, alteration, repair, improper installation, or improper testing. Warranty Limitations and Exclusions These warranties replace all other warranties, expressed or implied including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
• North America and Latin America To obtain warranty repair for the product, please go to the following Web site to obtain instructions: http://support.intel.com/support/ motherboards/draform.htm • In Europe and in Asia Contact your original authorized distributor for warranty service. Any replacement Product is warranted under this written warranty and is subject to the same limitations and exclusions for the remainder of the original warranty period.
96 Intel® Server System SR1560SF Service Guide
Appendix G: Installation/Assembly Safety Instructions English The power supply in this product contains no user-serviceable parts. Refer servicing only to qualified personnel. Do not attempt to modify or use the supplied AC power cord if it is not the exact type required. A product with more than one power supply will have a separate AC power cord for each supply. The power button on the system does not turn off system AC power.
After you have completed the six SAFETY steps above, you can remove the system covers. To do this: 1. Unlock and remove the padlock from the back of the system if a padlock has been installed. 2. Remove and save all screws from the covers. 3. Remove the cover(s). For proper cooling and airflow, always reinstall the chassis covers before turning on the system. Operating the system without the covers in place can damage system parts. To install the covers: 1.
Deutsch Benutzer können am Netzgerät dieses Produkts keine Reparaturen vornehmen. Das Produkt enthält möglicherweise mehrere Netzgeräte. Wartungsarbeiten müssen von qualifizierten Technikern ausgeführt werden. Versuchen Sie nicht, das mitgelieferte Netzkabel zu ändern oder zu verwenden, wenn es sich nicht genau um den erforderlichen Typ handelt. Ein Produkt mit mehreren Netzgeräten hat für jedes Netzgerät ein eigenes Netzkabel.
SICHERHEISMASSNAHMEN: Immer wenn Sie die Gehäuseabdeckung abnehmen um an das Systeminnere zu gelangen, sollten Sie folgende Schritte beachten: 1. Schalten Sie alle an Ihr System angeschlossenen Peripheriegeräte aus. 2. Schalten Sie das System mit dem Hauptschalter aus. 3. Ziehen Sie den Stromanschlußstecker Ihres Systems aus der Steckdose. 4. Auf der Rückseite des Systems beschriften und ziehen Sie alle Anschlußkabel von den I/O Anschlüssen oder Ports ab. 5.
Das System wurde für den Betrieb in einer normalen Büroumgebung entwickelt.
CONSIGNES DE SÉCURITÉ -Lorsque vous ouvrez le boîtier pour accéder à l'intérieur du système, suivez les consignes suivantes: 1. Mettez hors tension tous les périphériques connectés au système. 2. Mettez le système hors tension en mettant l'interrupteur général en position OFF (bouton-poussoir). 3. Débranchez tous les cordons d'alimentation c.a. du système et des prises murales. 4. Identifiez et débranchez tous les câbles reliés aux connecteurs d'E-S ou aux accès derrière le système. 5.
Danger d'explosion si la batterie n'est pas remontée correctement. Remplacer uniquement avec une batterie du même type ou d'un type équivalent recommandé par le fabricant. Disposez des piles usées selon les instructions du fabricant. Le système a été conçu pour fonctionner dans un cadre de travail normal. L'emplacement choisi doit être: • "Propre et dépourvu de poussière en suspension (sauf la poussière normale). • "Bien aéré et loin des sources de chaleur, y compris du soleil direct.
Nótese que el interruptor activado/desactivado en el panel frontal no desconecta la corriente alterna del sistema. Para desconectarla, deberá desenchufar todos los cables de corriente alterna de la pared o desconectar la fuente de alimentación. INSTRUCCIONES DE SEGURIDAD: Cuando extraiga la tapa del chasis para acceder al interior del sistema, siga las siguientes instrucciones: 1. Apague todos los dispositivos periféricos conectados al sistema. 2.
Si el sistema ha estado en funcionamiento, el microprocesador y el disipador de calor pueden estar aún calientes. También conviene tener en cuenta que en el chasis o en el tablero puede haber piezas cortantes o punzantes. Por ello, se recomienda precaución y el uso de guantes protectores. Existe peligro de explosión si la pila no se cambia de forma adecuada. Utilice solamente pilas iguales o del mismo tipo que las recomendadas por el fabricante del equipo.
Chinese Italiano Rivolgersi ad un tecnico specializzato per la riparazione dei componenti dell'alimentazione di questo prodotto. È possibile che il prodotto disponga di più fonti di alimentazione. Non modificare o utilizzare il cavo di alimentazione in c.a. fornito dal produttore, se non corrisponde esattamente al tipo richiesto. Ad ogni fonte di alimentazione corrisponde un cavo di alimentazione in c.a.
Dopo aver seguito i sei passi di SICUREZZA sopracitati, togliere le coperture del telaio del sistema come seque: 1. Aprire e rimuovere il lucchetto dal retro del sistema qualora ve ne fosse uno installato. 2. Togliere e mettere in un posto sicuro tutte le viti delle coperture. 3. Togliere le coperture. Per il giusto flusso dell'aria e raffreddamento del sistema, rimettere sempre le coperture del telaio prima di riaccendere il sistema.
108 Intel® Server System SR1560SF Service Guide
Appendix H: Safety Information English Server Safety Information This document applies to Intel® Server Boards, Intel® Server Chassis (pedestal and rackmount) and installed peripherals. To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in this guide before installing or maintaining your Intel® Server Product.
Indicates do not touch fan blades, may result in injury. Indicates to unplug all AC power cord(s) to disconnect AC power Please recycle battery Intended Application Uses This product was evaluated as Information Technology Equipment (ITE), which may be installed in offices, schools, computer rooms, and similar commercial type locations.
Power and Electrical Warnings Caution: The power button, indicated by the stand-by power marking, DOES NOT completely turn off the system AC power, 5V standby power is active whenever the system is plugged in. To remove power from system, you must unplug the AC power cord from the wall outlet. Your system may use more than one AC power cord. Make sure all AC power cords are unplugged. Make sure the AC power cord(s) is/are unplugged before you open the chassis, or add or remove any non hot-plug components.
System Access Warnings Caution: To avoid personal injury or property damage, the following safety instructions apply whenever accessing the inside of the product: • Turn off all peripheral devices connected to this product. • Turn off the system by pressing the power button to off. • Disconnect the AC power by unplugging all AC power cords from the system or wall outlet. • Disconnect all cables and telecommunication lines that are connected to the system.
Electrostatic Discharge (ESD) Caution: ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground -- any unpainted metal surface -- on your server when handling parts. Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges.
Deutsch Sicherheitshinweise für den Server Das vorliegende Dokument bezieht sich auf Intel® Serverplatinen, Intel® Servergehäuse (Standfuß und Rack) sowie installierte Peripheriegeräte. Es enthält Warnungen und Vorsichtsmaßnahmen zur Vermeidung von Gefahren durch Verletzung, Stromschlag, Feuer und Beschädigungen von Geräten. Lesen Sie diese Dokument daher sorgfältig, bevor Sie Ihr Intel® Serverprodukt installieren oder warten.
Weist darauf hin, daß das Anfassen des Gebläses zu Verletzungen führen kann. Bedeutet, alle Netzkabel abzuziehen und das Gerät von der Netzspannung zu trennen. Bereiten Sie bitte Batterie auf Zielbenutzer der Anwendung Dieses Produkt wurde in seiner Eigenschaft als IT-Gerät getestet, das in Büros, Schulen, Computerräumen und ähnlichen öffentlichen Räumlichkeiten installiert werden kann. Die Eignung dieses Produkts für andere Einsatzbereiche als IT (z. B.
Warnungen zu Netzspannung und Elektrizität Caution: Durch Betätigen der mit dem Standby-Symbol gekennzeichneten Netztaste wird das System NICHT vollständig vom Netz getrennt. Es sind weiterhin 5 V aktiv, solange das System eingesteckt ist. Um das System vollständig vom Strom zu trennen, muß das Netzkabel aus der Steckdose abgezogen werden. Das System verfügt möglicherweise über mehrere Netzkabel. Vergewissern Sie sich in diesem Fall, daß alle Netzkabel abgezogen sind.
Warnhinweise für den Systemzugang Caution: Um Verletzungen und Beschädigungen zu vermeiden, sollten Sie vor Arbeiten im Produktinneren folgende Sicherheitsanweisungen beachten: • Schalten Sie alle am Produkt angeschlossenen Peripheriegeräte aus. • Schalten Sie das System mit dem Netzschalter aus. • Trennen Sie das Gerät von der Stromquelle, indem Sie alle Netzkabel vom System bzw. aus der Steckdose ziehen. • Ziehen Sie alle Kabel und alle an das System angeschlossenen Telekommunikationsleitungen ab.
Sie müssen für die gesamte Rack-Einheit einen Netztrennschalter einrichten. Dieser Netztrennschalter muß leicht zugänglich sein und über eine Kennzeichnung verfügen, die besagt, daß er die Stromzufuhr zur gesamten Einheit steuert und nicht nur zu den Servern. Zur Vermeidung von Stromschlaggefahr müssen das Rack selbst und alle darin eingebauten Geräte ordnungsgemäß geerdet sein.
• Prüfen Sie, ob Kabel, Erweiterungskarten sowie weitere Komponenten ordnungsgemäß angebracht sind. • Befestigen Sie die Abdeckungen am Gehäuse des Produkts, wie in dessen Anleitung beschrieben. Laser-Peripheriegeräte oder -Komponenten Caution: Beachten Sie zur Vermeidung von Strahlung und Verletzungen die folgenden Hinweise: • Öffnen Sie keinesfalls das Gehäuse von Laser-Peripheriegeräten oder LaserKomponenten.
ATTENTION Indique la présence d’un risque pouvant entraîner des blessures physiques mineures ou endommager légèrement le matériel si la mise en garde n’est pas prise en compte. AVERTISSEMEN T Indique la présence d’un risque pouvant entraîner des blessures corporelles graves si l’avertissement n’est pas pris en compte. Indique un risque potentiel si les informations signalées ne sont pas prises en compte.
• Dans les régions sujettes aux orages magnétiques, nous vous recommandons de brancher votre système à un suppresseur de surtension et de déconnecter les lignes de télécommunication de votre modem pendant les orages. • Équipé d’une prise murale reliée à la terre. • Équipé d’un espace suffisant pour accéder aux cordons d’alimentation secteur, car ils servent de disjoncteur principal d’alimentation du produit.
niveaux dangereux de tension, de courant et d’énergie. Renvoyez-le au fabricant en cas de problème. Lorsque vous remplacez un bloc d’alimentation à chaud, débranchez le cordon du bloc d’alimentation en cours de remplacement avant de le retirer du serveur. Pour éviter tout risque d’électrocution, mettez le système hors tension et débranchez les cordons d’alimentation ainsi que les systèmes de télécommunication, réseaux et modems reliés au système avant d’ouvrir ce dernier.
• Mettez toutes les vis ou autres attaches de côté lorsque vous retirez les panneaux d’accès. Une fois que vous avez terminé d’accéder à l’intérieur du produit, refixez le panneau d’accès avec les vis ou attaches d’origine. • N’essayez pas d’accéder à l’intérieur du bloc d’alimentation. Il ne contient aucune pièce réparable. Renvoyez-le au fabricant en cas de problème.
Décharges électrostatiques (ESD) Attention:Les décharges électrostatiques (ESD) peuvent endommager les lecteurs de disque dur, les cartes et d’autres pièces. Il est fortement conseillé d’effectuer l’ensemble des procédures décrites à un poste de travail protégé contre les ESD.
Périphériques laser Attention:Pour éviter tout risque d’exposition aux rayonnements et/ou de dommage personnel: • N’ouvrez pas l’enceinte d’un périphérique laser. • Les périphériques laser ne sont pas réparables par l’utilisateur. • Retournez-les au fabricant en cas de problème. Español Información de seguridad del servidor Este documento se aplica a las tarjetas de servidor de Intel®, las carcasas de servidor de Intel® (montaje en bastidor y en pedestal) y los dispositivos periféricos.
Indica un riesgo potencial si no se tiene en cuenta la información indicada. Indica riesgo de descargas eléctricas que podrían causar lesiones graves o la muerte si no se siguen las instrucciones de seguridad. Indica componentes o superficies calientes. Indica que no se deben tocar las aspas de los ventiladores, ya que de lo contrario se podrían producir lesiones.
Manipulacién del equipo Reduzca el riesgo de daños personales o en el equipo: • Respete los requisitos de sanidad y seguridad laborales de su país cuando traslade y levante el equipo. • Utilice medios mecánicos u otros que sean adecuados al trasladar o levantar el equipo. • Para que el peso sea menor para manipularlo con más facilidad, extraiga los componentes que sean de fácil extracción.
Precaución: Para evitar descargas eléctricas o fuego, revise los cables de alimentación que usará con el producto tal y como se describe a continuación: • No intente modificar ni utilizar los cables de alimentación de CA si no son exactamente del modelo especificado para ajustarse a las tomas de corriente conectadas a tierra.
• Al reemplazar una fuente de alimentación de conexión en funcionamiento, desenchufe el cable de alimentación de la fuente de alimentación que va a reemplazar antes de extraerla del servidor. Precaución: Si el servidor se ha estado ejecutando, los procesadores y disipadores de calor estarán recalentados. A no ser que esté instalando o extrayendo un componente de conexión en funcionamiento, deje que el sistema se enfríe antes de abrir las cubiertas.
Descarga electrostática (ESD) Precaución: Las descargas electrostáticas pueden dañar las unidades de disco, las tarjetas y otros componentes. Recomendamos que realice todos los procedimientos en una estación de trabajo protegida contra descargas electrostáticas.
Enfriamiento y circulación de aire Precaución: El tendido de los cables debe realizarse cuidadosamente tal y como se le indica para reducir al mínimo los problemas de obstrucción de la ventilación y de refrigeración. Para conseguir una refrigeración y corriente de aire adecuadas, compruebe que cuando sistema esté funcionando, las cubiertas de la carcasa están instaladas. Si utiliza el sistema sin las cubiertas, podría dañar sus componentes.
132 Intel® Server System SR1560SF Service Guide
预期应用使用 根据评估,本产品为信息技术设备 (ITE),可安装在办公室、学校、计算机房和类似的商业场所。本产品对于非 ITE 应用的其他产品种类和环境(如医疗、工业、住宅、报警系统和测试设备)的适用 性尚有待进一步的评估。 场地选择 本系统专为在典型办公环境运行而设计。请选择符合以下条件的地点: • • • • • • • 清洁、干燥,无气载微粒(而非一般的室内尘埃)。 通风良好,远离热源(包括直接日晒和散热器)。 远离振动源或物理震动。 与电气设备产生的强大电磁场隔离。 在易受闪电袭击的地区,我们建议将系统插入电涌抑制器并在闪电期间断开通信 线路与调制解调器之间的连接。 提供正确接地的墙壁插座。 提供足够的空间,以便拿取电源供应线,因为这是本产品的主要电源断开器。 设备操作规范 减少人身伤害或设备受损的危险: • • • 移举设备时遵守当地的职业健康与安全要求。 借助机械手段或其他合适的手段移举设备。 拆除一切易分离组件,以降低重量并方便操作。 电源与电气警告 注意事项 电源按钮(如待机电源标记所示)并不能完全关闭系统的交流电源,只要系统已接 通电源,就存在 5V 待机电源。要从系统切断电源,须
为避免电击,请在打开服务器之前,关闭服务器并断开服务器上连接的电源线、电 信系统、网络和调制解调器。 电源线警告 如果产品未提供交流电线,请购买一根您所在国家批准使用的交流电线。 注意事项 为避免电击或火灾危险,请按如下所述对产品所用的电源线进行检查: • • • • 若非所需的符合接地插座的确切类型,请勿尝试修改或使用交流电线 电源线须符合以下标准: ⎯ 电源线的电气额定值须大于产品上标注的电流额定值。 ⎯ 电源线须拥有适合插座的安全接地插头或触点。 电源线为交流电源的主要断开设备。插座须靠近设备并可随时断开。 电源线须插入所提供的拥有合适接地的插座。 系统使用警告 注意事项 为避免人身伤害或财产损失,无论何时检查产品内部,以下安全指导都适用: • • • • • • • • 关闭所有与本产品相连的外设。 按下电源按钮至关闭状态,关闭系统。 从系统或墙壁插座上拔下所有交流电线,断开交流电源。 断开与系统相连的所有线缆和通信线路。 卸除舱口盖时,保留所有螺钉及其他紧固件。完成产品内部检查之后,请 用螺钉或紧固件重新固定舱口盖。 请勿打开电源供应设备。电源供应设备内没有可维修部件。请与生产商联系 维
注意事项 为避免受伤,请勿触摸运转的风机叶片。如果系统的风机上配有防护装置,请勿卸 下风机防护装置运行系统。 机架固定件警告 设备的机架须固定在稳固的支座上,以防从中安装服务器或设备时倒塌。须按照机 架生产商提供的安装说明进行安装。 从下往上将设备安装在机架上,最重的设备安装在机架的最底层。 一次只从机架上安装一件设备。 您须负责安装整个机架装置的主要电源断开设备。此主要断开设备须随时可用,且 须标明为控制整个装置(而不仅限于服务器)的电源。 为避免潜在的电击危险,须对机架及其上所安装的每一件设备实行正确的安全接地 。 静电放电 (ESD) 注意事项 ESD 会损坏磁盘驱动器、主板及其他部件。我们建议您执行 ESD 工作站的所有步骤。如果没有 ESD 工作站,则采取一些静电放电保护措施,操作部件时,戴上与服务器上的机箱接地 或任何未喷漆金属表面连接的防静电腕带。 操作主板时始终保持小心。它们可能对 ESD 非常敏感。拿持主板时只接触边缘。从保护包装中或从服务器上取出主板后,请将 主板组件侧面朝上放置在无静电的接地表面上。请使用导电泡沫垫(若有),不要 使用主板包装。请勿将主板在任何表面上滑动。 Inte
其他危险 替换电池 注意事项 不正确替换电池可能导致爆炸危险。替换电池时,请只使用设备生产商推荐使用的 电池。 请按当地法规处置电池。 请勿对电池充电。 请勿拆卸、刺穿或以其他方式损坏电池。 冷却和气流 注意事项 按照说明小心布置线缆,尽量减少气流阻塞和冷却问题。 为保证适当的冷却和气流,运行系统时请确保机箱盖已安装。未安装机箱盖即运行 系统可能导致系统部件受损。安装机箱盖的步骤如下: • • • 首先检查并确保系统内没有遗留的未固定工具或部件。 检查线缆、内插板和其他组件已正确安装。 按产品说明安装机箱盖。 激光外设或激光设备 注意事项 为避免幅射暴露和 / 或人身伤害: • 请勿打开任何激光外设或激光设备的外壳 • 激光外设或激光设备为非用户维修设备 请与生产商联系维修事宜 136 Intel® Server System SR1560SF Service Guide