Technical Product Specification
Intel® Server System SR1560SF TPS Appendix D: Jumper Block Settings and Usage
Revision 1.2 69
Intel order number D92959-006
Appendix D: Jumper Block Settings and Usage
The server board has several 2-pin and 3-pin jumper blocks that can be used to configure,
protect, or recover specific features of the server board. Pin 1 on each jumper block is denoted
by an “*” or “▼”.
Recovery Jumper Blocks
Table 50. Recovery Jumpers
Jumper Name Pins What happens at system reset
1-2
BMC Firmware Force Update Mode – Disabled (Default)
BMC Force
Update
2-3 BMC Firmware Force Update Mode – Enabled
1-2
These pins should have a jumper in place for normal system operation. (Default)
Password Clear
2-3 If these pins are jumpered, administrator and user passwords will be cleared
immediately. These pins should not be jumpered for normal operation.
1-2
These pins should have a jumper in place for normal system operation. (Default)
CMOS Clear
2-3 If these pins are jumpered, the CMOS settings will be cleared immediately. These pins
should not be jumpered for normal operation
Figure 35. Recovery Jumper Blocks
AF002170
3
2
Disable
Enable
3
2
CMOS
Clear
3
2
BMC Force
Update Mode
Password
Reset