5. Peripheral Drive Support
The system provides a slim-line drive bay that can be populated with an IDE optical drive (CD-
ROM, DVD, DVD/CDR) or a USB floppy drive. Drives are mounted on a tool-less tray which
allows for easy installation into and removal from the system. The slim-line devices are not hot-
swappable.
AF002198
Figure 17. View of Slim-line Drive Bay
5.1 USB Floppy Drive Support
Systems configured with a hot-swap backplane have the option to install a slim-line USB floppy
drive kit (Intel Product Code AXXUSBFLOPPY). The floppy drive can be inserted into either the
slim-line bay or the hard drive bay directly below the slim-line bay. The option kit includes the
necessary cables and trays to support either configuration. Once inserted into the drive bay, the
floppy drive is cabled to a four pin USB connector on the backplane. The following table
provides the pin-out for the USB connector.
Table 24. 4-pin USB Floppy Connector Pin-out
Pin # Pin Definition
1 Power
2 USB_P3n
3 USB P3p
4 Ground