Technical Product Specification

Power Sub-System Intel® Server System SR1560SF TPS
Revision 1.2
Intel order number D92959-006
18
Table 14. AC Line Surge Transient Performance
AC Line Surge
Duration Surge Operating AC Voltage Line Frequency Performance Criteria
Continuous 10% Nominal AC Voltages 50/60Hz No loss of function or performance
0 to ½ AC
cycle
30% Mid-point of nominal AC
Voltages
50/60Hz No loss of function or performance
3.4.2 Susceptibility Requirements
The power supply meets the following electrical immunity requirements:
Table 15. Performance Criteria
Level Description
A The apparatus shall continue to operate as intended. No degradation of performance.
B The apparatus shall continue to operate as intended. No degradation of performance
beyond spec limits.
C Temporary loss of function is allowed provided the function is self-recoverable or can be
restored by the operation of the controls.
3.4.2.1 Electrostatic Discharge Susceptibility
The power supply complies with the limits defined in EN 55024: 1998 using the IEC 61000-4-
2:1995 test standard and performance criteria B defined in Annex B of CISPR 24.Tested to
meet the level 3 requirement.
3.4.2.2 Fast Transient/Burst
The power supply complies with the limits defined in EN55024: 1998 using the IEC 61000-4-
4:1995 test standard and performance criteria B defined in Annex B of CISPR 24. Test to meet
the level 3 requirement.
3.4.2.3 Radiated Immunity
The power supply complies with the limits defined in EN55024: 1998 using the IEC 61000-4-
3:1995 test standard and performance criteria A defined in Annex B of CISPR 24.
3.4.2.4 Surge Immunity
The power supply was tested with the system for immunity to AC Ringwave and AC
Unidirectional wave, both up to 2kV, per EN 55024:1998, EN 61000-4-5:1995 and ANSI C62.45:
1992.
The pass criteria include: No unsafe operation is allowed under any condition; all power supply
output voltage levels to stay within proper spec levels; No change in operating state or loss of
data during and after the test profile; No component damage under any condition.
The power supply complies with the limits defined in EN55024: 1998 using the IEC 61000-4-
5:1995 test standard and performance criteria B defined in Annex B of CISPR 24.