Intel® Server System SR1560SF Technical Product Specification Intel order number D92959-006 Revision 1.
Revision HistoryReference Documents Intel® Server System SR1560SF TPS Revision History ii Date Revision Number April 2007 May 2007 0.5 0.9 August 2007 0.95 September 2007 November 2008 1.0 1.1 May 2010 1.
Intel® Server System SR1560SF TPS DisclaimersReference Documents Disclaimers Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document.
Table of Contents Intel® Server System SR1560SF TPS Table of Contents 1. Introduction .......................................................................................................................... 1 1.1 Chapter Outline........................................................................................................ 1 1.2 Server Board Use Disclaimer .................................................................................. 1 2. Product Overview....................................
Intel® Server System SR1560SF TPS Table of Contents 5.1 USB Floppy Drive Support..................................................................................... 29 5.2 Optical Drive Support............................................................................................. 30 6. Hard Disk Drive Support.................................................................................................... 31 6.1 Hard Drive Trays.....................................................................
List of Figures Intel® Server System SR1560SF TPS List of Figures Figure 1. Top Down View – Fixed Mount Hard Drive SKU .............................................. 5 Figure 2. Top Down View – Hot-Swap Drive SKU........................................................... 6 Figure 3. Major Chassis Components ............................................................................. 7 Figure 4. Drive Bay Overview..........................................................................................
Intel® Server System SR1560SF TPS List of Figures Figure 37. External RJ45 Serial Port Configuration Jumper.......................................... 72 Revision 1.
List of Tables Intel® Server System SR1560SF TPS List of Tables Table 1. System Feature Set........................................................................................... 3 Table 2. Processor Support Matrix .................................................................................. 4 Table 3. Chassis Dimensions.......................................................................................... 6 Table 4. Drive Overview ..............................................................
Intel® Server System SR1560SF TPS List of Tables Table 37. Add-in Card Connector Pin-out (J4B3 – Passive Only) ................................. 45 Table 38. Control Button and Intrusion Switch Functions.............................................. 48 Table 39. Control Panel LED Functions ........................................................................ 48 Table 40. SSI Power LED Operation............................................................................. 49 Table 41.
List of Tables Intel® Server System SR1560SF TPS < This page intentionally left blank > x Intel order number D92959-006 Revision 1.
Intel® Server System SR1560SF TPS 1. Introduction Introduction This Technical Product Specification (TPS) provides system specific information detailing the features, functionality, and high level architecture of the Intel® Server System SR1560SF. The Intel® Server Board S5400SF Technical Product Specification should also be referenced to obtain greater detail of functionality and architecture specific to the integrated server board, but which are also supported on this server system.
Introduction Intel® Server System SR1560SF TPS conditions. Intel Corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits. 2 Intel order number D92959-006 Revision 1.
Intel® Server System SR1560SF TPS 2. Product Overview Product Overview The Intel® Server System SR1560SF is a rack mount 1U server system with features that are designed to support the high-density high performance computing server market.
Product Overview Intel® Server System SR1560SF TPS Feature Description Hard Drive Controller Options Integrated ESB2-E 3Gb/s SATA ports, for use in Fixed Drive and Passive Backplane configurations LSI* LSISAS1064E SAS/SATA controller RAID Controller, integrated on Active SAS backplane option for use in hot swap backplane configuration Support for Intel® Embedded Server RAID Technology II with SW RAID levels 0/1/10. Optional support for SW RAID 5 with activation key.
Intel® Server System SR1560SF TPS 2.1 Product Overview System Views Figure 1. Top Down View – Fixed Mount Hard Drive SKU Revision 1.
Product Overview Intel® Server System SR1560SF TPS Figure 2. Top Down View – Hot-Swap Drive SKU 2.2 System Dimensions Table 3. Chassis Dimensions 6 Height 43.25 mm 1.703” Width without rails 430 mm 16.930” Width with rails 451.3 mm 17.77” Depth without CMA 692 mm 27.25” Depth with CMA 838.2 mm 33.0” Max. Weight (Fixed drive version) 13.38 kg 29.5 lbs Max. Weight (Hot-Swap drive version) 14.29 kg 31.5 lbs Intel order number D92959-006 Revision 1.
Intel® Server System SR1560SF TPS 2.
Product Overview 2.4 Intel® Server System SR1560SF TPS Hard Drive and Peripheral Bays Table 4.
Intel® Server System SR1560SF TPS Product Overview Server Board Overview Figure 5. Intel® Server Board S5400SF Revision 1.
Product Overview Intel® Server System SR1560SF TPS The following figure shows the board layout of the server board.
Intel® Server System SR1560SF TPS S T Product Overview System Fan 1 ATA-100 Optical Drive Connector (Power+IO) MM NN OO System Fan 3 System Fan 4 Serial ‘A’ Header Figure 6.
Product Overview Intel® Server System SR1560SF TPS B C A D G E F AF002160 A Description Diagnostic LEDs E Description Processor 2 Fault LED B System ID LED F Processor 1 Fault LED C Status LED G 5V Standby LED D DIMM Fault LEDs Figure 8. Light Guided Diagnostics LED Locations 12 Intel order number D92959-006 Revision 1.
Intel® Server System SR1560SF TPS 2.5 Product Overview Front Bezel Support The optional front bezel is made of molded plastic and uses a snap-on design. When installed, its design allows for maximum airflow to maintain system cooling requirements. (Intel Product Code – ADWBEZBLACK). Light pipes in the front bezel supporting the standard control panel allow the system status LEDs to be monitored with the bezel installed. A Ventilation B Key Lock C System Status LEDs Figure 9.
Power Sub-System 3. Intel® Server System SR1560SF TPS Power Sub-System The power sub-system consists of a single non-redundant 600 W High Efficiency power supply with eight outputs; 3.3V, 5V, 12V1, 12V2, 12V3, 12V4, -12V and 5VSB. The input are auto ranging and power factor corrected. The form factor is SSI EPS1U at 240mm depth and wire harness output.
Intel® Server System SR1560SF TPS Power Sub-System 3.2 Output Connectors The power supply has a cable harness with four power connectors used to power various platform sub-systems. The following table defines each power connector Table 5.
Power Sub-System Intel® Server System SR1560SF TPS P2 – Processor Power Connector Connector housing: 8-Pin Molex 39-01-2085 or equivalent Contact: Molex, Mini-Fit Jr, HCS, 44476-1111 or equivalent Table 7.
Intel® Server System SR1560SF TPS Power Sub-System 3.3 Efficiency The following table provides the required minimum efficiency level at various loading conditions. These are provided at three different load levels; 100%, 50% and 20%. Efficiency was tested over an AC input voltage range of 115VAC to 220VAC. Table 11. Power Supply Efficiency Loading Minimum Efficiency 3.
Power Sub-System Intel® Server System SR1560SF TPS Table 14. AC Line Surge Transient Performance Duration Continuous 0 to ½ AC cycle 3.4.2 Surge 10% 30% Operating AC Voltage Nominal AC Voltages Mid-point of nominal AC Voltages AC Line Surge Line Frequency 50/60Hz 50/60Hz Performance Criteria No loss of function or performance No loss of function or performance Susceptibility Requirements The power supply meets the following electrical immunity requirements: Table 15. Performance Criteria 3.4.2.
Intel® Server System SR1560SF TPS 3.4.3 Power Sub-System AC Line Fast Transient (EFT) Specification The power supply meets the EN61000-4-5 directive and any additional requirements in IEC1000-4-5:1995 and the Level 3 requirements for surge-withstand capability, with the following conditions and exceptions: These input transients must not cause any out-of-regulation conditions, such as overshoot and undershoot, nor must it cause any nuisance trips of any of the power supply protection circuits.
Power Sub-System Intel® Server System SR1560SF TPS brownout shall not blow the fuse. The power supply will tolerate a 3min ramp from 90VAC voltage to 0VAC after the components have reached a steady state condition. 3.4.5.2 Voltage Interruptions The power supply complies with the limits defined in EN55024: 1998 using the IEC 61000-411:1995 test standard and performance criteria C defined in Annex B of CISPR 24. 3.4.
Intel® Server System SR1560SF TPS Power Sub-System supply will shutdown and latch off. The latch will be cleared by toggling the PSON# signal or by an AC power interruption. The power supply will not be damaged from repeated power cycling in this condition. -12V and 5VSB will be protected under over-current or shorted conditions so that no damage can occur to the power supply. Auto-recovery feature is a requirement on 5VSB rail. Table 17. Over-current Protection (OCP) VOLTAGE +3.
Power Sub-System 3.6 Intel® Server System SR1560SF TPS Power Supply Status LED There is a single bi-color LED to indicate the power supply status. The LED operation is defined in the following table. Table 19. LED Indicators Power Supply Condition No AC power to all power supplies 3.
Intel® Server System SR1560SF TPS 4. Cooling Sub-System Cooling Sub-System The system components that make up the cooling sub-system include: five managed 40x40x56mm dual rotor fans, two 40x40x28mm power supply fans, a CPU air duct, and an air baffle. Together, these components provide the necessary airflow needed to meet the thermal requirements of the system when operating within specified thermal limits. See Table 44. System Environmental Limits Summary.
Cooling Sub-System Intel® Server System SR1560SF TPS Table 20.
Intel® Server System SR1560SF TPS 4.1.1 Cooling Sub-System System Fan Board A system fan board is used in systems configured to support fixed mount hard drives. The system fan board is used to provide power to each system fan, and used as a communication interconnect between each fan and the server board, allowing for server management to monitor and manage each fan. The system fan board also includes a fan fault LED for each system fan. The LED functionality is controlled by server management software.
Cooling Sub-System Intel® Server System SR1560SF TPS Pin Definition PCI_FAN_TACH9 PCI_FAN_TACH10 Pin # 23 25 24 26 Pin Definition CONN_PIN24_R FM_SIO_TEMP_SENSOR The system fan board includes a 2x4 power connector which is connected with the P3 power harness of the power supply. The connector has the following pin-out Table 23. System Fan Board Power Connector (J3B1) Pin-out Pin Definition +12V +12V +5V Standby +3.3V 4.
Intel® Server System SR1560SF TPS Cooling Sub-System For dual processor configurations, the air dam must be snapped off of the CPU air duct. Failure to remove the air dam will prevent the installation of the air duct into the system. Once removed, the air damn cannot be re-connected to the air duct. Figure 15. CPU Air Duct Note: IMPORTANT: With only one processor installed in the system, do NOT remove the air dam from the underside of the CPU air duct.
Cooling Sub-System 4.5 Intel® Server System SR1560SF TPS DIMM Slot Blanks The use of DIMM slot blanks is required if the system is configured with up to eight x4 FBDIMMs which do NOT have an AMB thermal sensor. When using this specific FBDIMM type, the system cannot provide adequate cooling to the DIMMs, unless DIMM slot blanks are inserted in the third slot of each memory channel (Slots: A3, B3, C3, and D3).
Intel® Server System SR1560SF TPS 5. Peripheral Drive Support Peripheral Drive Support The system provides a slim-line drive bay that can be populated with an IDE optical drive (CDROM, DVD, DVD/CDR) or a USB floppy drive. Drives are mounted on a tool-less tray which allows for easy installation into and removal from the system. The slim-line devices are not hotswappable. AF002198 Figure 17. View of Slim-line Drive Bay 5.
Peripheral Drive Support 5.2 Intel® Server System SR1560SF TPS Optical Drive Support The system has support for a slim-line IDE optical drive. The drive is mounted onto a tool-less drive tray and is connected to an interposer card attached to the tray. The drive assembly is then inserted in to the slim-line drive bay. A 44-pin ribbon cable is used to connect the drive assembly to a matching IDE connector on the server board. Table 25.
Intel® Server System SR1560SF TPS 6. Hard Disk Drive Support Hard Disk Drive Support The Intel® Server System SR1560SF is available in two hard drive configurations; fixed drive SATA and hot-swap SATA/SAS. The hard drive bays are designed to support tray mounted 3.5” x 1” hard drives. Depending on the configuration, the system can either support up to two fixed mount SATA drives, or up to three hot-swap SATA or SAS drives. A B AF002197 A Slim Line Optical Drive B Hard Drive Bays Figure 18.
Hard Disk Drive Support Intel® Server System SR1560SF TPS A E B C D AF002199 Figure 20. Hot-Swap Hard Drive Tray Assembly 6.2 Fixed Mount Hard Drive Support One option of the Intel® Server System SR1560SF is able to support up to two fixed mount SATA hard drives. In this configuration, there is no backplane installed. Instead, each installed hard drive is cabled to SATA ports on the server board or add-in card.
Intel® Server System SR1560SF TPS 6.3.1 Hard Disk Drive Support Backplane Feature set: Vitesse* VSC410 enclosure management controller Integrated v3000 32 bit RISC microprocessor core External non-volatile Flash ROM Four I2C interfaces 44 GPIO pins Three drive control connectors supporting either SATA ports from the server board or SAS/SATA ports from an add-in card (passive backplane only) * LSI LSISAS1064E SAS/SATA controller (active backplane only) Four-port, 3.
Hard Disk Drive Support Intel® Server System SR1560SF TPS A B C D E F G H I J K L M O N TP02171 A B C D E F G H Backplane Power USB Floppy Connector SATA 0 SATA 1 SATA 2 Fan 5 Power Bridge Board Connector Fan 4 Power I J K L M N O Fan 3 Power Fan 2 Power Front Panel Connector Fan 1 Power Screw Front Panel USB SATA/SAS connectors to HDD Figure 21. Hot-swap Passive SAS/SATA Backplane Layout 34 Intel order number D92959-006 Revision 1.
Intel® Server System SR1560SF TPS Hard Disk Drive Support A B C D E F G H I J K M L TP02172 A B C D E F G Backplane Power USB Floppy Connector SW RAID Activation Key Connector Fan 5 Power Bridge Board Connector Fan 4 Power Fan 3 Power H I J K L M Fan 2 Power Front Panel Connector Fan 1 Power Screw Front Panel USB SAS/SATA connectors to HDD Figure 22. Active SAS Backplane Layout Revision 1.
Hard Disk Drive Support Intel® Server System SR1560SF TPS The following figures show the functional blocks for each backplane: Passive Backplane 7-Pin Drive Control Connectors x3 17-Pin SAS/SATA HDD Connectors x3 I2C and GPIO Server Board Bridge Board USB 3 Activity Signals HDD Status LED x3 Fault Signals VSC410 Enclosure Management 1x4 Pin USB Floppy Drive Connector 2x25 Pin Control Panel I/O Connector USB 1 and 2 1x10 Pin Control Panel USB Connector PWM and Fan System Fan Connectors x5 TP0
Intel® Server System SR1560SF TPS 6.3.1.1 Hard Disk Drive Support Vitesse* VSC410 Enclosure Management Controller Both the active and passive backplanes support enclosure management using a Vitesse* VSC410 management controller. The VSC410 drives the hard drive activity/fault LED, hard drive present signal, and controls hard drive power up during system power on.
Hard Disk Drive Support Intel® Server System SR1560SF TPS The SAS interface uses the proven SCSI command set to ensure reliable data transfers, while providing the connectivity and flexibility of point-to- point serial data transfers. The SAS interface provides improved performance, simplified cabling, smaller connectors, lower pin count, and lower power requirements when compared to parallel SCSI.
Intel® Server System SR1560SF TPS 6.3.2 Hard Disk Drive Support LED Support The backplanes support an activity/fault LED for each of the hard drive connectors. The LED will illuminate green for activity or amber for a drive fault. The green activity LED is driven by the SAS/SATA hard disk drive directly. The amber fault LED is driven by the VSC410* management controller whenever a fault condition is detected.
Hard Disk Drive Support 6.3.3.2 Intel® Server System SR1560SF TPS Bridge Board Interface (Backplane to Server Board) The backplanes provide a pathway for the control panel, PCIe*, USB, and other miscellaneous signals from the server board to connector interfaces on the backplane. The server board and backplane have matching 120-pin connectors which are attached using a PCB called the Bridge Board, as shown in the following figure.
Intel® Server System SR1560SF TPS Hard Disk Drive Support PIin SIignal Name 20 FM_RAID_MODE 21 GND 22 CLK_IOP_DN 23 CLK_IOP_DP 24 GND 25 SGPIO_DATAOUT1 26 SGPIO_DATAOUT0 27 SGPIO_LOAD 28 SGPIO_CLOCK 29 GND 30 USB2_ESB_DP 31 USB2_ESB_DN 32 GND 33 USB2_ESB_OC_N 34 NIC1_LINK_LED_N 35 NIC1_ACT_LED_N 36 LED_STATUS_AMBER_R1 37 NIC2_LINK_LED_N 38 NIC2_ACT_LED_N 39 LED_STATUS_GREEN_BUF_R1 40 GND 41 SMB_PBI_5VSB_DAT 42 SMB_PBI_5VSB_CLK 43 GND 44 V_IO_HSYNC2_BUF_FP 45 V_IO_VSYNC2_BUF_FP 46 GND 47 V_IO_BLUE_CONN_FP
Hard Disk Drive Support 6.3.3.3 Intel® Server System SR1560SF TPS Control Panel I/O Interface Connector (Backplane to Control Panel) The backplanes provide a pathway for control panel I/O signals from the bridge board connector to the control panel interface connector. The pin-out for the 50-pin control panel I/O connector is shown in the following table: Table 30.
Intel® Server System SR1560SF TPS 6.3.3.5 Hard Disk Drive Support Hot-Swap SATA/SAS Drive Connectors The backplanes provide three hot-swap SATA/SAS connectors, which provide power and signals using a single docking connector. Each drive attaches to the backplane using one of these connectors. Table 32. SAS/SATA Hard Drive Connector Pin-out (J8N1, J6N1, J3N1) Pin# SI S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 S13 S14 P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 P11 P12 P13 P14 P15 PTH0 PTY1 6.3.3.
Hard Disk Drive Support 6.3.3.7 Intel® Server System SR1560SF TPS USB Floppy Drive Connector With a slim-line USB floppy drive installed (using the optional floppy drive kit) into either the slim-line drive bay or in one of the hard drive bays, the USB floppy cable is routed from the drive to a 4-pin connector on the backplane. The following table provides the pin-out for the floppy drive connector. Table 34. 4-pin Floppy Connector Pin-out (J2B1) Pin# 1 2 3 4 6.3.3.
Intel® Server System SR1560SF TPS 6.3.3.9 Hard Disk Drive Support System Management Connectors The backplanes provide connectors to interface with system management buses. The following tables define the pin-out for each of these connectors: Table 36. IPMB Connector Pin-out (J1C1) Pin # 1 2 3 4 Description SMB_IPMB_5VSB_DAT GND SMB_IPMB_5VSB_CLK SMB_PWR_IPMB_CONN Table 37. Add-in Card Connector Pin-out (J4B3 – Passive Only) Pin # 1 2 3 Revision 1.
Standard Control Panel Functionality 7. Intel® Server System SR1560SF TPS Standard Control Panel Functionality The Intel® Server System SR1560SF can support either of two standard control panels; one each for the fixed drive and hot-swap backplane configurations. The control panel assemblies are pre-assembled and modular in design. The entire module assembly slides into a predefined slot in the front of the chassis. AF002202 Figure 27.
Intel® Server System SR1560SF TPS Standard Control Panel Functionality For systems configured with a hot-swap backplane, the standard control panel supports several push buttons and status LEDs, along with USB and video ports to centralize system control, monitoring, and accessibility to within a common compact design. The following diagram overviews the layout and functions of the control panel.
Standard Control Panel Functionality Intel® Server System SR1560SF TPS Table 38. Control Button and Intrusion Switch Functions Reference A 7.2 B Feature Power/Sleep Button ID Button C D Reset Button NMI Button Function Toggles the system power on/off. This button also functions as a Sleep Button if enabled by an ACPI-compliant operating system. Toggles the front panel ID LED and the baseboard ID LED on/off.
Intel® Server System SR1560SF TPS LED Standard Control Panel Functionality Color System Identification Off 3 On Off Off Blue Off State Description No hard disk activity Identify active via command or button. No Identification. Notes: 1. 2. 3. 4. Blink rate is ~1 Hz with at 50% duty cycle. The amber status takes precedence over the green status. When the amber LED is on or blinking, the green LED is off. Also off when the system is powered off (S4/S5) or in a sleep state (S1).
Standard Control Panel Functionality Color State Intel® Server System SR1560SF TPS Criticality Description In mirrored configuration, when memory mirroring takes place and system loses memory redundancy. This is not covered by (2). Redundancy loss such as power-supply or fan. This does not apply to non-redundant sub-systems. PCIe* link errors CPU failure/disabled – if there are two processors and one of them fails Fan alarm – Fan failure.
Intel® Server System SR1560SF TPS Standard Control Panel Functionality The blue “System ID” LED can be illuminated using either of the following two mechanisms: - By pressing the system ID button on the system control panel the ID LED will display a solid blue color, until the button is pressed again.
PCI Rise Card and Assembly 8. Intel® Server System SR1560SF TPS PCI Riser Card and Assembly The Intel® Server System S1560SF provides one x16 PCI Express* Gen 2 PCI riser slot supporting a one slot x16 PCI Express* riser card capable of supporting full length full height PCI Express* add-in cards. When re-inserting the riser assembly into the chassis, tabs on the back of the assembly should be aligned with slots on the back edge of the chassis.
Intel® Server System SR1560SF TPS Environmental and Regulatory Specifications 9. Environmental and Regulatory Specifications 9.1 System Level Environmental Limits The table below defines the system level operating and non-operating environmental limits: Table 44.
Environmental and Regulatory Specifications 9.3 Intel® Server System SR1560SF TPS Replacing the Back up Battery The lithium battery on the server board powers the real time clock (RTC) for up to 10 years in the absence of power. When the battery starts to weaken, it loses voltage, and the server settings stored in CMOS RAM in the RTC (for example, the date and time) may be wrong. Contact your customer service representative or dealer for a list of approved devices.
Intel® Server System SR1560SF TPS 9.4 Environmental and Regulatory Specifications Product Regulatory Compliance The server chassis product, when correctly integrated per this guide, complies with the following safety and electromagnetic compatibility (EMC) regulations. Intended Application – This product was evaluated as Information Technology Equipment (ITE), which may be installed in offices, schools, computer rooms, and similar commercial type locations.
Environmental and Regulatory Specifications Intel® Server System SR1560SF TPS The following table references Server Chassis Compliance and markings that may appear on the product. Markings below are typical markings however, may vary or be different based on how certification is obtained. Note: Certifications Emissions requirements are to Class A. Table 45.
Intel® Server System SR1560SF TPS Compliance Regional Description Environmental and Regulatory Specifications Compliance Reference Compliance Reference Marking Example GOST-R Certification GOST R 29216-91 (Emissions) Russia GOST R 50628-95 (Immunity) Ukraine Ukraine Certification Taiwan BSMI CNS13438 None Required R33025 9.6 Electromagnetic Compatibility Notices 9.6.1 USA This device complies with Part 15 of the FCC Rules.
Environmental and Regulatory Specifications Intel® Server System SR1560SF TPS Only peripherals (computer input/output devices, terminals, printers, etc.) that comply with FCC Class B limits may be attached to this computer product. Operation with noncompliant peripherals is likely to result in interference to radio and TV reception. All cables used to connect to peripherals must be shielded and grounded.
Intel® Server System SR1560SF TPS Environmental and Regulatory Specifications This is a Class A product based on the standard of the Voluntary Control Council For Interference (VCCI) from Information Technology Equipment. If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. 9.6.
Environmental and Regulatory Specifications 9.7 Intel® Server System SR1560SF TPS Product Ecology Compliance Intel has a system in place to restrict the use of banned substances in accordance with world wide product ecology regulatory requirements. The following is Intel’s product ecology compliance criteria. Compliance Regional Description California China Compliance Reference California Code of Regulations, Title 22, Division 4.5; Chapter 33: Best Management Practices for Perchlorate Materials.
Intel® Server System SR1560SF TPS Compliance Regional Description Intel Internal Specification International Environmental and Regulatory Specifications Compliance Reference All materials, parts and subassemblies must not contain restricted materials as defined in Intel’s Environmental Product Content Specification of Suppliers and Outsourced Manufacturers – http://supplier.intel.com/ehs/environmental.htm ISO11469 - Plastic parts weighing >25gm are intended to be marked with per ISO11469.
Environmental and Regulatory Specifications 9.8 Intel® Server System SR1560SF TPS Other Markings Compliance Description Stand-by Power Compliance Reference Compliance Reference Marking Example 60950 Safety Requirement Applied to product is stand-by power switch is used. . Multiple Power Cords 60950 Safety Requirement Applied to product if more than one power cord is used. English: This unit has more than one power supply cord.
Intel® Server System SR1560SF TPS Appendix A: Integration and Usage Tips Appendix A: Integration and Usage Tips This section provides a list of useful information that should be referenced before attempting to integrate and configure your Intel Server System SR1560SF. After the system is integrated with processors, memory, and peripheral devices, the FRUSDR utility must be run to load the proper Sensor Data Record data to the integrated Server Management subsystem.
Appendix B: POST Code Diagnostic LED Decoder Intel® Server System SR1560SF TPS Appendix B: POST Code Diagnostic LED Decoder During the system boot process, BIOS executes a number of platform configuration processes, each of which is assigned a specific hex POST code number. As each configuration routine is started, BIOS will display the given POST code to the POST Code Diagnostic LEDs found on the back edge of the server board.
Intel® Server System SR1560SF TPS Appendix B: POST Code Diagnostic LED Decoder Table 47.
Appendix B: POST Code Diagnostic LED Decoder Diagnostic LED Decoder G=Green, R=Red, A=Amber MSB LSB Keyboard (PS2 or USB) Intel® Server System SR1560SF TPS Description Checkpoint 0x90h R OFF OFF R Resetting the keyboard 0x91h R OFF OFF A Disabling the keyboard 0x92h R OFF G R Detecting the presence of the keyboard 0x93h R OFF G A Enabling the keyboard 0x94h R G OFF R Clearing keyboard input buffer 0x95h R G OFF A Instructing keyboard controller to run Self Test (PS2 o
Intel® Server System SR1560SF TPS Checkpoint 0xE1h 0xE3h Appendix B: POST Code Diagnostic LED Decoder Diagnostic LED Decoder G=Green, R=Red, A=Amber MSB LSB R R R G R R A G Description Reserved for initialization module use (PEIM) Reserved for initialization module use (PEIM) Driver Execution Environment (DXE) Core 0xE4h R A R OFF 0xE5h R A R G Started dispatching drivers Entered EFI driver execution phase (DXE) 0xE6h R A A OFF Started connecting drivers R A A G DXE Drivers 0x
Appendix C: POST Error Beep Codes Intel® Server System SR1560SF TPS Appendix C: POST Error Beep Codes The following table lists POST error beep codes. Prior to system video initialization, BIOS uses these beep codes to inform users on error conditions. The beep code is followed by a user visible code on POST progress LEDs. Table 48.
Intel® Server System SR1560SF TPS Appendix D: Jumper Block Settings and Usage Appendix D: Jumper Block Settings and Usage The server board has several 2-pin and 3-pin jumper blocks that can be used to configure, protect, or recover specific features of the server board. Pin 1 on each jumper block is denoted by an “*” or “▼”. Recovery Jumper Blocks Table 50.
Appendix D: Jumper Block Settings and Usage Intel® Server System SR1560SF TPS CMOS Clear and Password Reset Usage Procedure The CMOS Clear and Password Reset recovery features are designed so that the desired operation can be achieved with minimal system down time. The usage procedure for these two features has changed from previous generation Intel® Server Boards. The following procedure outlines the new usage model. CMOS Clear Procedure: 1. Power down the server; do not remove AC power. 2.
Intel® Server System SR1560SF TPS Appendix D: Jumper Block Settings and Usage 6. Power down and remove AC power. 7. Open the server and move the jumper from the “enabled” position (pins 2-3) to the “disabled” position (pins 1-2). 8. Close the server system and reconnect AC power and power up the server. Note: Normal BMC functionality is disabled with the force BMC update jumper set to the “enabled” position.
Appendix D: Jumper Block Settings and Usage Intel® Server System SR1560SF TPS External RJ45 Serial Port Jumper Block The jumper block J9D1, located directly behind the external RJ45 serial port, is used to configure either a DSR or a DCD signal to the connector. J8A3 2 3 4 1-2: DCD to DTR 3-4: DSR to DTR (factory default) AF002172 Figure 37. External RJ45 Serial Port Configuration Jumper 72 Intel order number D92959-006 Revision 1.
Intel® Server System SR1560SF TPS Glossary Glossary Term ACPI Advanced Configuration and Power Interface Definition AP Application Processor APIC Advanced Programmable Interrupt Control ASIC Application Specific Integrated Circuit ASMI Advanced Server Management Interface BIOS Basic Input/Output System BIST Built-In Self Test BMC Baseboard Management Controller Bridge Circuitry connecting one computer bus to another, allowing an agent on one to access the other BSP Bootstrap Processor
Glossary Intel® Server System SR1560SF TPS Term IPMI Intelligent Platform Management Interface Definition IR Infrared ITP In-Target Probe KB 1024 bytes KCS Keyboard Controller Style LAN Local Area Network LCD Liquid Crystal Display LED Light Emitting Diode LPC Low Pin Count LUN Logical Unit Number MAC Media Access Control MB 1024KB MCH Memory Controller Hub MD2 Message Digest 2 – Hashing Algorithm MD5 Message Digest 5 – Hashing Algorithm – Higher Security ms milliseconds M
Intel® Server System SR1560SF TPS Glossary Term SMS Server Management Software Definition SNMP Simple Network Management Protocol TBD To Be Determined TIM Thermal Interface Material UART Universal Asynchronous Receiver/Transmitter UDP User Datagram Protocol UHCI Universal Host Controller Interface UTC Universal time coordinate VID Voltage Identification VRD Voltage Regulator Down Word 16-bit quantity ZIF Zero Insertion Force Revision 1.
Reference Documents Intel® Server System SR1560SF TPS Reference Documents See the following documents for additional information: 76 Intel® Server Board S5400SF Technical Product Specification Intel® 5400 Series Server Board BIOS External Product Specification Intel® 5400 Series Server Board Baseboard Management Controller External Product Specification Intel® 5400 Memory Controller Hub External Design Specification Intel® Enterprise South Bridge-2 (ESB2-E) External Design Specificati