Technical Product Specification

Intel® Server Boards S5000PSL and S5000XSL TPS Appendix B: BMC Sensor Tables
Revision 1.7
Intel order number: D41763-008
81
Sensor
Name
[1]
Sensor
Number
System
Applica-
bility
Sensor Type Event/Rea
ding Type
Event Offset
Triggers
Criticality Assert/De-a
ssert
Readable
Value/Offse
ts
Event Data Rearm Standby
Power
Gauge
(aggregate
power)
Power
Supply 2
7Dh Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc] Threshold
defined
As and De Analog R, T A, I
System
ACPI Power
State
82h All System ACPI
Power State
22h
Sensor
Specific
6Fh
S0/G0
S1
S3
S4
S5/G2
G3 mechanical off
OK As Trig Offset A, I X
Button 84h All Button
14h
Sensor
Specific
6Fh
Power button
Reset button
OK As Trig Offset A, I X
SMI Timeout 85h All SMI Timeout
F3h
Digital
Discrete
03h
01h – State
asserted
Critical As and De Trig Offset A, I
Sensor
Failure
86h All Sensor
Failure
F6h
OEM
Sensor
Specific
73h
I
2
C device not
found
I
2
C device error
detected
I
2
C bus timeout
OK As Trig Offset A X
NMI Signal
State
87h All OEM
C0h
Digital
Discrete
03h
01h – State
asserted
OK – 01h A, I
SMI Signal
State
88h All OEM
C0h
Digital
Discrete
03h
01h – State
asserted
OK – 01h A, I
IERR Critical
Thermal trip Critical
Config error Critical
Proc 1
Status
90h All Processor
07h
Sensor
Specific
6Fh
Presence OK
As and De Trig Offset M X