Technical Product Specification

Appendix B: BMC Sensor Tables Intel® Server Boards S5000PSL and S5000XSL TPS
Revision 1.7
Intel order number: D41763-008
80
Sensor
Name
[1]
Sensor
Number
System
Applica-
bility
Sensor Type Event/Rea
ding Type
Event Offset
Triggers
Criticality Assert/De-a
ssert
Readable
Value/Offse
ts
Event Data Rearm Standby
Presence
OK
Failure Degraded
Predictive fail Degraded
A/C lost Degraded
Power
Supply
Status
[5]
2
71h
Chassis-
specific
Power Supply
08h
Sensor
Specific
6Fh
Configuration error OK
As and De Trig Offset A X
Power
Nozzle
Power
Supply 1
78h Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc] Threshold
defined
As and De Analog R, T A, I
Power
Nozzle
Power
Supply 2
79h Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc] Threshold
defined
As and De Analog R, T A, I
Power
Gauge
V1 rail
(+12V)
Power
Supply 1
7Ah Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc] Threshold
defined
As and De Analog R, T A, I
Power
Gauge
V1 rail
(+12v)
Power
Supply 2
7Bh Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc] Threshold
defined
As and De Analog R, T A, I
Power
Gauge
(aggregate
power)
Power
Supply 1
7Ch Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc] Threshold
defined
As and De Analog R, T A, I