Server Board Family Datasheet

System BIOS Intel® S5000 Server Board Family Datasheet
Revision 1.3
Intel order number D38960-006
54
The BIOS provides data to the BMC telling it which fan profile the platform is setup for,
Acoustics Mode or Performance Mode. The BIOS uses the parameters retrieved from the
thermal sensor data records (SDR), the fan profile setting from BIOS Setup, and the altitude
setting from BIOS Setup to configure the system for memory throttling and fan speed control. If
the BIOS fails to get the Thermal SDRs, then it will use the Memory Reference Code (MRC)
default settings for the memory throttling settings.
The <F2> BIOS Setup Utility provides options to set the fan profile or operating mode the
platform will operate under. Each operating mode has a predefined profile for which specific
platform targets are configured, which in turn determines how the system fans operate to meet
those targets. Platform profile targets are determined by which type of platform is selected when
running the FRUSDR utility and by BIOS settings configured using the <F2> BIOS Setup Utility.
3.4.2.3 Configuring the Fan Profile Using the BIOS Setup Utility
The BIOS uses options set in the <F2> BIOS Setup Utility to determine what fan profile the
system should operate under. These options include “SET FAN PROFILE” and “ALTITUDE”.
The “SET FAN PROFILE” option can be set to either the “Performance” mode (Default), or
“Acoustics” mode. See the following sections for detail describing the difference between each
mode. Changing the fan profile to Acoustics mode may affect system performance.
The “ALTITUDE” option is used to determine appropriate memory performance settings based
on the different cooling capability at different altitudes. At high altitude, memory performance
must be reduced to compensate for thinner air. Be advised, selecting an Altitude option to a
setting that does not meet the operating altitude of the server may limit the system fans ability to
provide adequate cooling to the memory. If the air flow is not sufficient to meet the needs of the
server even after throttling has occurred, the system may shut down due to excessive platform
thermals.
By default, the Altitude option is set to 301Meters – 900 Meters which is believed to cover the
majority of the operating altitudes for these server platforms.
The following Diagrams show which BIOS Setup Utility menu is used to configure the desired
Fan Profile.
Advanced
System Acoustic and Performance Configuration
Throttling Mode Open Loop / Closed Loop
Set Fan Profile Performance / Acoustics
Altitude 300 M or less / 301 M - 900 M / Higher than 900 M