Server Board Family Datasheet
Intel® S5000 Server Board Family Datasheet System BIOS
Revision 1.3
Intel order number D38960-006
49
Table 11. Runtime Memory Error Handling, No Redundancy
Scenario POST Message SEL LED State IPMI MEM States
Updated
System Operation
Runtime:
Config != RAS
Correctable Errors
(CE) < Threshold
None, because the
BIOS does not retain
the memory state
information across
reboots.
CE SEL message with DIMM
location
DIMM fault LED: Not lit.
System fault LED: Not lit.
No The system
continues to
operate.
Runtime:
Config != RAS
CE >= Threshold
None, because the
BIOS does not retain
the memory state
information across
reboots.
CE SEL message
CE Threshold Reached
message
CE Logging Stopped
DIMM LED: Lit for the failed
FBDIMM only.
System fault LED:
Green / blink: more than
one FBDIMM installed.
Amber / on: Only one
FBDIMM is installed.
Fail Status = Y
Disabled Status = N
The system
continues to
operate normally,
but will mask all
correctable memory
errors.
Runtime: Config !=
RAS UE
None, because the
BIOS does not retain
the memory state
information across
reboots.
UE identifying the FBDIMM
location
DIMM fault LED: Lit for the
lockstepped pair or for a single
FBDIMM, depending upon the
mode of operation.
System fault LED: Amber / on.
Fail status = Y
Disabled Status = Y
The system will