Technical Advisory 892
Copyright © 2008 Intel Corporation. * Other names and brands may be claimed as the property of others.
3. Wait approximately 30 seconds before beginning the HSC firmware update. The 30 second delay will give the Intel
®
RMM2 and BMC time to complete communication before switching tasks.
4. Proceed with the HSC firmware update.
5. Once complete, type these two commands to restart the Intel
®
RMM2 communications.
(locally) "kiratool -a cfg set ipmi.medium._c_ i2c"
"kiratool -a reset"
(Or remotely) "kiratool -a -l <ip#> -u <username> -p <password> cfg set ipmi.medium._c_ i2c"
"kiratool -a -l <ip#> -u <username> -p <password> reset"
Refer to the documentation for Kiratool for additional information.
Note: Intel server S7000FC4UR requires the use of the username and password for local or remote connections. In
addition, this Intel server does not support DOS based utilities. Use the WinPE, Linux or EFI versions of kiratool.
Please contact your Intel Sales Representative if you require more specific information about this issue.
Enterprise Platforms & Services Division
Intel Corporation