Specification Update

Monthly Specification Update Enterprise Platforms and Services Marketing
21
revision: SAS firmware revision -- v.01.16.00.00; MPT OpROM revision --
v.6.10.00; SAS ESRT2 OpROM v. A.01.10241435I.
Workaround None.
38. POST screen may generate “NMI has been received – System Halted”
message after the system reboots
Problem POST screen may generate "NMI has been received - System Halted"
message after the system reboots.
Implication Along with this error, sometimes “Bus Uncorrectable Error” might also be
recorded to System Event Log (SEL).
Status This erratum is fixed in BIOS release R0066 and later releases.
Workaround Reboot the system again.
39. S5000PSLSAS software RAID 5 cannot be configured
Problem When users install the SAS software RAID 5 key on the board, there is no SAS
software RAID 5 option that displays in the SAS RAID configuration menu.
Implication This problem may occur because of old versions of SAS RAID firmware on the
server board.
Status This erratum was fixed in Intel
®
Embedded Server RAID Technology II firmware
revision: SAS firmware revision -- v.01.16.00.00; MPT OpROM revision --
v.6.10.00; SAS ESRT2 OpROM v. A.01.10241435I.
Workaround None.
40. SuSE* Linux Enterprise Server unable to boot after basic installation
Problem During a SuSE* Linux Enterprise Server installation, if a USB floppy drive is
used to load the mass storage driver, SuSE* Linux Enterprise Server may not
boot after basic installation. The following message may display:
resume device /dev/sdb1 not found (ignoring)
waiting for device /dev/sdb2 to
appear..............................not found -- exiting
to /bin/sh
$