21. System fault LED may report incorrect status for some events
Problem The system fault LED may report incorrect status for some events. The proper
LED state is described in the server board TPS, but some events may not
reflect the states described in the TPS.
Implication The user may receive incorrect indication via the system fault LED. The user
should verify the system state by looking at the SEL. No event is reported as a
less severe status than expected, but may display with a higher severity status.
Status This erratum was fixed with BIOS R0065, BMC 55 and FRUSDR 40.
Workaround None
22. Fan removal does not generate SEL event
Problem Fan removal does not trigger a fan failure event.
Implication Fan removal generates a “fan presence deassertion” event instead of a fan
failure event. When the fan is reinstalled, a “fan presence assertion” event is
generated.
Status No fix.
Workaround None.
23. Power supply redundancy state is misleading when only one power
supply is installed
Problem If a single power supply is installed in a chassis that supports redundant power
supplies, the BMC indicates the power supply redundancy state as redundant.
Implication In a single power supply configuration, ignore the redundancy sensor.
Redundant chassis with fully redundant power supplies will accurately reflect
the redundancy status.
Status This erratum was fixed by BMC 36 and FRUSDR 20.
Workaround None.