Specification Update
Enterprise Platforms and Services Marketing Monthly Specification Update
8
Errata
1. Console Redirection baud rate setting auto changing to 19.2K with Serial
Over LAN (SOL) active
Problem If configuring an SOL connection, the only baud rate allowed is 19.2K. If any
other baud rate is selected, the system will always revert back to 19.2K after
the DC cycle.
Implication Users who require a different baud rate for their application cannot configure
this.
Status This erratum was fixed in BIOS revision R0045.
Workaround None.
2. Serial Over LAN (SOL) unable to redirect DOS output
Problem No SOL output is seen when booted to DOS. SOL will only redirect F2 Setup
and POST output.
Implication Users who require SOL to redirect DOS output cannot use this feature.
Status This erratum was fixed in BIOS revision R0054.
Workaround None.
3. Password on boot not supported
Problem If an “admin” or “user” password is set in the BIOS setup, this is required before
the user can access the BIOS Setup. There is no option to configure a
password during POST before the server will boot.
Implication Users cannot create and require a password on boot.
Status Intel does not intend to fix this erratum.
Workaround None