Specification Update
Enterprise Platforms and Services Marketing Monthly Specification Update
6
No. Plans Description of Errata
19. Fixed SEL events for HSC may appear after DC cycle.
20. Fixed Fans may run faster than expected after exiting BIOS setup.
21. Fixed System fault LED may report incorrect status for some events.
22. No Fix Fan removal does not generate SEL even.
23. Fixed Power supply redundancy state is misleading when only one power supply is installed.
24. No Fix PCI-X slots 1 and 2 do not meet the letter of the Server System Infrastructure (SSI) Entry-
Level Electronics Bay (EEB) Specification revision 3.61.
25. Fixed Serial ATA (SATA) HDDs may be marked offline when populated behind a second Serial
Attached SCSI (SAS) expander based drive enclosure.
26. Fixed Failures seen installing to a SATA drive when SATA is set to Legacy in the BIOS setup.
27. Fixed System Hangs after disabling onboard video in the BIOS setup.
28. Fixed The SMBIOS entry point may not be visible under certain hardware configurations.
29. Fixed Fans occasionally running too fast after the BIOS reset.
30. Fixed SAS SW RAID option is erroneously available in the BIOS setup after loading optimal
default settings on the S5000PSLROMB server board.
31. Fix RAID Web Console 2 Utility displays “Unexpected Sensor” warning message in Microsoft
Windows* operating system.
32. Fixed PS/2 keyboards and mice may stop functioning after Red Hat* Enterprise Linux is installed.
33. Fix HSC and LCP updates may take a long time.
34. No Fix SuSE* Linux Enterprise Server may not install successfully with Intel
®
Embedded Server
RAID Technology II enabled.
35. No Fix Red Hat* Enterprise Linux 4 and the BIOS setup display a different L2 cache size for the
Intel
®
Xeon
®
Processor 5300 Series.
36. Fixed Change Logo Utility causes BIOS corruption.
37. Fixed Microsoft Windows System Event Viewer* may record ID 11 error event.
38. Fixed POST screen may generate “NMI has been received – System Halted” message after the
system reboots.
39. Fixed S5000PSLSAS software RAID 5 cannot be configured.
40. No Fix SuSE* Linux Enterprise Server unable to boot after basic installation.
41. No Fix Red Hat* Enterprise Linux may report the wrong processor speed.
42. Fixed A kernel panic is likely to be observed with Red Hat* Enterprise Linux 4 or SuSE* Linux
Enterprise Server 9 when SpeedStep is disabled in the BIOS menu.
43. Fixed SAS software RAID 5 activation key may NOT be detected.
44. Fixed Microsoft Windows* operating systems without the service pack will exhibit blue screen with
BIOS BIO79 and 81.
45. Fixed Fails PXE boot from on-board NIC 2 and neither on-board NIC works under DOS with BIOS
R0079 and R0081.
46. Fixed SAS Embedded Server RAID Technology II RAID 5 consistence check fails in ESRTII BIOS
console only if hard drives docked in expander HSBP.
47. Fixed Sluggish system performance may be experienced with BMC60.
48. Fixed Microsoft Windows Server 2003* R2 SP2 may exhibit blue screen during an operating
system boot or shutdown with a specific version of I/OAT driver.
49. Fixed Recent Intel
®
Server RAID Adapters fail to activate RAID BIOS Console by Ctrl+G in
S5000PSL and/or S5000XVN PCI slot 4.
50. Fixed Microsoft Windows Server 2008* and/or Microsoft Windows Vista* may report Performance
Power Management error.