Specification Update

Monthly Specification Update Enterprise Platforms and Services Marketing
5
Summary Tables of Changes
The following tables indicate the errata and the document changes that apply to the Intel
®
Server Boards S5000PSL and S5000XSL. Intel intends to fix some of the errata in a future
stepping of components and to account for the other outstanding issues through documentation
or specification changes as noted. The tables use the following notations:
Doc:
Intel intends to update the appropriate documentation in a future revision.
Fix:
Intel intends to fix this erratum in a future release of the component.
Fixed:
This erratum was previously fixed.
No Fix:
There are no plans to fix this erratum.
Shaded:
This erratum is either new or was modified from the previous specification
update.
Table 1. Errata Summary
No. Plans Description of Errata
1. Fixed Console Redirection Baud Rate Setting auto changing to 19.2K with Serial Over LAN (SOL)
active.
2. Fixed Serial Over LAN (SOL) unable to redirect DOS output.
3. No Fix Password on boot not supported.
4. Fixed SAS Software RAID option is not enabled in the initial BIOS release.
5. Fixed Secondary HSC backplane FW not visible in the BIOS setup.
6. Fixed HSC and BMC versions intermittently not seen in the BIOS setup.
7. Fixed POST LEDs do not turn off after operating system loads.
8. Fixed Checkup7.exe (microcode update utility) is not storing microcode in the BIOS.
9. Fixed Intel
®
Server RAID Card SRCSAS144E causes systems to reset multiple times before
completing POST.
10. Fixed Change Logo utility does not save modified BIOS capsule files with correct extension.
11. Fix IPMI over Serial direct connect not supported.
12. Fix Serial over LAN and IPMI over LAN connections may terminate unexpectedly under certain
conditions.
13. Fixed Intermittent beep code 1-5-2-1 when booting with dual processors.
14. Fixed Power Supply population errors may not appear in SEL.
15. Fix Fan 5 may report a reading of 0 RPM after BMC is updated.
16. Fixed BMC may not respond to the IPMI command, Send Message sent via LAN.
17. Fix Fans may take a long time to slow down after fan boosting.
18. Fixed System requires approximately 35 seconds after AC power applied before power button
responds.