Product User Guide
10
2.3.1 Installation on Intel
®
Server Board S5000XAL / S5000PAL
The Intel
®
Server Board S5000XAL / S5000PAL installs in rack mount 1U or 2U chassis. The
same installation steps apply to both chassis types.
• The Intel
®
RMM2 module ships with one plastic standoff pre-installed as shown in
Figure 2. The standoff will align with a hole in the server baseboard when mounted to
the baseboard.
• Attach the Intel
®
RMM2 to the connector on the server baseboard labeled “RMM”.
Snap the standoff into the corresponding hole in the baseboard.
• Next, insert three plastic standoffs into the holes of the Intel
®
RMM2 NIC module. See
Figure 3.
• Push out and remove the metal cover on the chassis where the NIC RJ-45 receptacle
will align.
• Mount the NIC module to the header on the baseboard and snap the three standoffs
into the corresponding holes in the baseboard. This will align the RJ-45 with the
opening in the chassis.
• Make a note of the MAC address of the Intel
®
RMM2. It is written on a label attached
to the module (not the NIC). Keeping a record now may eliminate the need to reopen
the cover later.
• Replace the chassis cover, attach AC power and connect a network cable to the Intel
®
RMM2 NIC.
AF002058
Figure 2: Installing the Intel
®
RMM2