Technical Product Specification
Appendix B: BMC Sensor Tables Intel® Server Boards S5000PSL and S5000XSL TPS
Revision 1.7
Intel order number: D41763-008
88
Sensor
Name
[1]
Sensor
Number
System
Applica-
bility
Sensor Type Event/Rea
ding Type
Event Offset
Triggers
Criticality Assert/De-a
ssert
Readable
Value/Offse
ts
Event Data Rearm Standby
Non-redundant:
sufficient
resources from
redundant
Non-redundant:
sufficient
resources from
insufficient
resources
Degraded
Mirroring
Redun-
dancy
0Ch 0Bh
Non-redundant:
insufficient
resources
Crtical
Notes:
1. Actual sensor name strings in SDR may vary from the names in this table, according to platform-specific usage.
2. Not supported, except for ESB2 embedded NICs.
3. The FBDIMM Aggregate sensor only has effect when CLTT is enabled.
4. For system with redundant cooling capability, the contribution to system status is determined by the fan redundancy sensor.
5. Sensor only presents status on systems that have applicable redundancy (for instance, redundant fan or power supply).
6. Applicable with Intel
®
Xeon
®
Processor 5000 series.
7. Applicable with Intel
®
Xeon
®
Processor 5100 series and 45-nm 2P Intel
®
Xeon
®
Processor.
8. Applicable with Intel
®
Xeon
®
Processor 5300 series and 45-nm 2P Intel
®
Xeon
®
Processor.