Technical Product Specification

Appendix B: BMC Sensor Tables Intel® Server Boards S5000PSL and S5000XSL TPS
Revision 1.7
Intel order number: D41763-008
82
Sensor
Name
[1]
Sensor
Number
System
Applica-
bility
Sensor Type Event/Rea
ding Type
Event Offset
Triggers
Criticality Assert/De-a
ssert
Readable
Value/Offse
ts
Event Data Rearm Standby
Disabled Degraded
IERR Critical
Thermal trip Critical
Config error Critical
Presence OK
Proc 2
Status
91h All Processor
07h
Sensor
Specific
6Fh
Disabled Degraded
As and De Trig Offset M X
Proc 1
Temp
[6]
98h All Temperature
01h
Threshold
01h
[u,l] [c,nc] Threshold
defined
As and De Analog R, T A, I
P1 Therm
Margin
[7]
99h All Temperature
01h
Threshold
01h
– – A, I
Proc 2
Temp
[6]
9Ah All Temperature
01h
Threshold
01h
[u,l] [c,nc] Threshold
defined
As and De Analog R, T A, I
P2 Therm
Margin
[7]
9Bh All Temperature
01h
Threshold
01h
– – A, I
P1B Therm
Margin
[8]
9Ch All Temperature
01h
Threshold
01h
– – A, I
P2B Therm
Margin
[8]
9Dh All Temperature
01h
Threshold
01h
– – A, I
Bus correctable
error
OK PCIe Link0 A0h All Sensor
Specific
6Fh
PCIe
Link0
Bus uncorrectable
error
Degraded
As – See the
BIOS EPS
A, i
Bus correctable
error
OK PCIe Link1 A1h All Sensor
Specific
6Fh
Sensor
Specific
6Fh
Bus uncorrectable
error
Degraded
As – See the
BIOS EPS
A, I
Bus correctable
error
OK PCIe Link2 A2h All Sensor
Specific
6Fh
Sensor
Specific
6Fh
Bus uncorrectable
error
Degraded
As – See the
BIOS EPS
A, I