Technical Product Specification
Intel® Server Boards S5000PSL and S5000XSL TPS Appendix B: BMC Sensor Tables
Revision 1.7
Intel order number: D41763-008
79
Sensor
Name
[1]
Sensor
Number
System
Applica-
bility
Sensor Type Event/Rea
ding Type
Event Offset
Triggers
Criticality Assert/De-a
ssert
Readable
Value/Offse
ts
Event Data Rearm Standby
Fan 7
Present
66h Chassis-
specific
Fan
04h
Generic
08h
Device present OK As and De – T A –
Fan 8
Present
67h Chassis-
specific
Fan
04h
Generic
08h
Device present OK As and De – T A –
Fan 9
Present
68h Chassis-
specific
Fan
04h
Generic
08h
Device present OK As and De – T A –
Fan 10
Present
69h Chassis-
specific
Fan
04h
Generic
08h
Device present OK As and De – T A –
Full redundant OK
Redundancy lost Degraded
Redundancy
degraded
Degraded
Non-redundant:
sufficient
resources from
redundant
Degraded
Non-redundant:
sufficient from
insufficient
Degraded
Non-redundant:
insufficient
Non
Critical
Redundant
degrade from full
Degraded
Fan Redun-
dancy
[5]
6Fh Chassis-
specific
Fan
04h
Generic
0Bh
Redundant
degrade from non-
redundant
Degraded
As and De – Trig Offset A X
Presence OK
Failure Degraded
Predictive fail Degraded
A/C lost Degraded
Power
Supply
Status
[5]
1
70h Chassis-
specific
Power Supply
08h
Sensor
Specific
6Fh
Configuration error OK
As and De – Trig Offset A X