Technical Product Specification
Intel® Server Boards S5000PSL and S5000XSL TPS Appendix B: BMC Sensor Tables
Revision 1.7
Intel order number: D41763-008
75
Table 50. BMC Sensors
Sensor
Name
[1]
Sensor
Number
System
Applica-
bility
Sensor Type Event/Rea
ding Type
Event Offset
Triggers
Criticality Assert/De-a
ssert
Readable
Value/Offse
ts
Event Data Rearm Standby
Power down
Power cycle
A/C lost
OK
Power Unit
Status
01h All Power Unit
09h
Sensor
Specific
6Fh
Soft power control
failure
Power unit failure
Crit
As and De – Trig Offset A, I X
Fully redundant OK
Redundancy Lost Degraded
Redundancy
degraded
Degraded
Non-redundant:
sufficient
resources from
redundant
Degraded
Non-redundant:
sufficient from
insufficient
Degraded
Non-redundant:
insufficient
Critical
Redundant
degrade from full
Degraded
Power Unit
Redun-
dancy
02h Chassis-
specific
Power Unit
09h
Generic
0Bh
Redundant
degrade from non-
redundant
Degraded
As and De – Trig Offset A X
Watchdog 03h All Watchdog 2
23h
Sensor
Specific
6Fh
Timer expired,
status only
Hard reset
Power down
Power cycle
Timer interrupt
OK As – Trig Offset A, I X