7.3.1 System Status LED – BMC Initialization
When the AC power is first applied to the system and 5V-STBY is present, the BMC
controller on the server board requires 5-10 seconds to initialize. During this time, the
system status LED blinks, alternating between amber and green, and the power button
functionality of the control panel is disabled preventing the server from powering up. Once
BMC initialization has completed, the status LED stops blinking and the power button
functionality is restored and can be used to turn on the server.
7.4 DIMM Fault LEDs
The server board provides a memory fault LED for each DIMM socket. These LEDs are located
towards the rear of the server board next to each DIMM connector.
AF000205
Figure 21. DIMM Fault LED Locations