42
Color
State
Criticality
Description
2. VRD Hot asserted.
3. One of the redundant power supplies failed.
4. Minimum number of fans to cool the system are not present or
have failed.
Amber
Solid on
Critical, non-
recoverable
Fatal alarm system has failed or shutdown
BIOS Detected
1. DIMM failure when there is one DIMM present and no good
memory is present.
1
2. Run-time memory uncorrectable error in non-redundant mode.
1
3. CPU configuration error (for instance, processor stepping
mismatch).
Integrated BMC Detected
11. CPU CATERR signal asserted.
12. CPU 1 is missing.
13. CPU THERMTRIP.
14. System cooling fan failure.
15. No power good redundant power fault.
Power Unit Redundancy sensor Insufficient resources
offset (indicates not enough power supplies are present).
Notes:
1. The BIOS detects these conditions and sends a Set Fault Indication command to the Integrated BMC to
provide the contribution to the system status LED.
2. Blink rate is ~ 1Hz at 50% duty cycle.
6.2.3 System Status LED BMC Initialization
When power is first applied to the system and 5V-STBY is present, the BMC controller on the
server board requires 15-20 seconds to initialize. During this time, the system status LED will be
solid on, both amber and green. Once BMC initialization has completed, the status LED will stay
green solid on. If power button is pressed before BMC initialization completes, the system will