System Service Guide

Appendix A: Technical Reference
Appendix A: Technical Reference
Power Supply Input Voltages
Table 8. CRPS Input Voltage
Parameter
Min
Rated
Max
Start up VAC
Power Off VAC
110V
AC
90 V
rms
100-127 V
rms
140 V
rms
85 V
AC
± 4V
AC
70V
AC
±5V
AC
220V
AC
180 V
rms
200-240 V
rms
264 V
rms
Frequency
47 Hz
50/60 Hz
63 Hz
Power Supply Output Voltages
Table 9. CRPS Output Voltage
Param
eter
Min Nom
Ma
x
Unit Tolerance
+12VSTB
+11.40V
+12.000V
+12.60V
Vrms
±5%
+12V
+11.40V
+12.000V
+12.60V
Vrms
±5%
System Environmental Specifications
The following table defines the system level operating and non-operating environmental limits.
Table 10. System Environmental Limits Summary
Parameter Limits
Operating Temperature
+10°C to +35°C with the maximum rate of change not to exceed 10°C per hour
Non-Operating Temperature -40°C to +70°C
Non-Operating Humidity 90%, non-condensing at 35°C
Acoustic noise Sound power:
- 3.5" HDD SKU: 6.9BA at idle and 7.4BA at active mode;
- 2.5" HDD SKU: 6.5BA at idle and 7.07BA at active mode.
Shock, operating Half sine, 2 g peak, 11 milliseconds
Shock, unpackaged Trapezoidal, 25 g, velocity change 136 inches/second (40 lbs to < 80 lbs)
Shock, packaged Non-palletized free fall in height 24 inches (40 lbs to < 80 lbs)
Vibration, unpackaged 5 Hz to 500 Hz, 2.20 g RMS random
ESD +/-12 KV except I/O port +/- 8 KV per Intel
®
Environmental test specification
60 Intel
®
Server System H2000WP Family Service Guide