Service Guide for Intel Server System H2000WP

Hardware Installations and Updates
20 Intel
®
Server System H2000WP Family Service Guide
Transparent Mylar Installation
In case IOM carrier on slot2 or PCIe add-in card on riser slot 1 is installed, the transparent Mylar*
attached to the air duct must be installed in between add-in card and rear IO bracket for isolation.
Figure 29. Transparent Isolation Film for Air Duct
Removing and Installing Processor
The heatsink has thermal interface material (TIM) on the underside of it. Use caution so that you do
not damage the thermal interface material. Use gloves to avoid sharp edges.
Removing Processor Heatsink(s)
The heatsink is attached to the server board/processor socket with captive fasteners. Using a #2
Phillips* screwdriver, loosen the four screws located on the heatsink corners in a diagonal manner
using the following procedure:
1. Using a #2 Phillips* screwdriver, start with screw 1 and loosen it by giving it two rotations
and stop (see letter A). (IMPORTANT: Do not fully loosen.)
2. Proceed to screw 2 and loosen it by giving it two rotations and stop (see letter B). Similarly,
loosen screws 3 and 4. Repeat steps A and B by giving each screw two rotations each time
until all screws are loosened.
3. Lift the heatsink straight up (see letter C).