Monthly Specification Update
Monthly Specification Update
Summary Tables of Changes
The following tables provide an overview of known errata and known document changes that
apply to the specified Intel
®
Server Boards or Intel
®
Server Systems. The tables use the
following notations:
Doc:
Intel intends to update the appropriate documentation in a future revision.
Fix:
Intel intends to fix this erratum in the future.
Fixed:
This erratum has been previously fixed.
NoFix:
There are no plans to fix this erratum.
Shaded:
This erratum is either new or has been modified from the previous specification
update.
Table 1. Errata Summary
No.
Plans
Description of Errata
1.
Fix
Linux* operating systems are not supported on SCU ports in RSTe mode.
2.
Fixed
UEFI Windows Server 2008* R2 SP1 installation on SCU ports may fail in RSTe RAID mode.
3.
No Fix
UEFI operating system installation is not supported in ESRT2 mode.
4.
Fixed
The HDD status LEDs do not function with specific configurations.
5.
Fixed
RSTe GUI installation may fail if no devices are attached to any on-board AHCI ports.
6.
Fixed
The BMC continuously sends the RAID volume rebuild events in RSTe mode of the SCU controllers.
7.
Fixed
The BIOS hangs if both “EFI Optimized Boot” and “Memory Mapped I/O Above 4GB” are enabled.
8.
Fixed
Microsoft Windows 2003* x86 installation fails in pass-through mode of the SCU controllers.
9.
Fixed
The system may halt with unsupported configurations in ESRT2 mode.
10.
Fixed
An extra event may be seen in the SEL during a system global reset.
11.
Fixed
The Minimum wattage reads as zero on the integrated BMC web console Power Statistics page.
12.
Fixed
The Perform Action button does not function on the integrated BMC web console Power Control
page.
13.
Fixed
The system may continuously report a fault or assert/de-assert log when having blank HDD carriers
or unconfigured HDDs.
14.
Fixed
The BIOS and ME firmware cannot be updated successfully using the Intel
®
One Boot Flash Update
Utility(OFU) for SUSE* Linux Enterprise Server 11 (64-bit) with SP2.
15.
Fixed
The BMC continuously sends an HDD assert/de-assert event during an HDD RAID rebuild in ESRT2
mode of the SCU controllers.
16.
Fixed
High CPU utilization may occur when installing or running Microsoft Windows Server 2008* R2 or
Microsoft Windows 7* with the default NIC driver for Intel
®
Gigabit ET Dual Port Server Adapter
E1G42ET and Intel
®
Gigabit ET Quad Port Server Adapter E1G44ET.
17.
Fixed
The power supply sensors may not be available after power cycles.
18.
Fixed
The chassis sags about 2.0 mm when fully loaded in the rack.
19.
Fixed
Incorrect picture titles in the Chassis Quick Reference.
20.
Fix
The system may halt with specific BIOS configurations.
21.
Fixed
Intel
®
LAN driver installation fails on Windows 7*.
2