Monthly Specification Update
Monthly Specification Update
Implication The LAN driver cannot be installed with the .bat installation scripts in the driver
package.
Status The issue is fixed in the Intel
®
LAN driver 17.1.
Workaround Two workarounds are available:
1. Install the LAN driver manually.
2. Lower the “User Account Control” to “Never Notify”, and then install the
driver with the .bat installation scripts.
22.
Exit Air Temp reading mismatch when using IPMI command in Linux*
Problem When using IPMI command “IPMI sensor list”, the normal sensor reading is:
Exit Air Temp | 38.000 | degrees C | ok | na | 5.000 |
10.000 | 80.000 | 85.000 | na
With the IPMI command “IPMITOOL BMC reset cold”, the following error may
occur:
Exit Air Temp | 41.000 | degrees C | cr | na | 0.000 |
0.000 | 0.000 | 0.000 | na
Implication This will generate the CRITICAL entry in the SEL.
Status The issue is fixed in the BMC 1.10 release.
Workaround The error reading may not occur by the next system reboot.
23.
Intel
®
RAID C600 upgrade key replacement issue
Problem With the Management Engineer (ME) firmware 02.01.05.069, the server may
detect the incorrect Storage Control Unit (SCU) Redundant Array of
Inexpensive/Independend Disks (RAID) informaion after installing or replacing
the RAID upgrade key. The board or system may still show the previous RAID
information even if you have replaced the key with a new one.
Implication With the ME firmware 02.01.05.069, the system may not detect the new RAID
activation key during the first AC power on.
Status This issue is fixed with the ME firmware 02.01.05.107 and later versions.
Workaround Do a second AC power cycle to the system after the RAID upgrade key has
been installed or replaced to ensure the corrrect type of key is identified.
12