Monthly Specification Update

Monthly Specification Update
Implication The SEL may indicate that the system has an occasional reset in a normal
POST during a DC cycle test (global reset).
Status This issue is fixed in the BMC 1.04.2896.
Workaround None.
11.
The Minimum wattage reads as zero on the integrated BMC web console
Power Statistics page
Problem In some systems the integrated BMC web console Power Statistic page may
display the Minimun wattage as zero (0W) after the system has been powered.
This reading will stay at zero until the next power cycle of the system.
Implication This is an incorrect reading only and does not affect the operation.
Status This issue is fixed in the BMC 1.10 and later releases.
Workaround None.
12.
The Perform Action button does not function on the integrated BMC
web console Power Control page
Problem After you perform a graceful shutdown from the integrated BMC web console
Power Control page, the Perform Action button gets grayed out and cannot be
pressed to request another action.
Implication The Perform Action button is grayed out.
Status This issue is fixed in the BMC 1.10 and later releases.
Workaround Select another page in the Integrated BMC Web Console and then return to the
Power Control page. Then the Perform Action button will be available.
13.
The system may continuously report a fault or assert/de-assert log
when having blank HDD carriers or unconfigured HDDs
Problem With ESRT2 SATA RAID 5 configured with three HDDs, put the fourth HDD in
the drive carrier and set it as either unconfigured or global hot spare. The
system event log may be flooded with HDD fault entries.
With ESRT2 SAS RAID 1 configured with two HDDs, put the third HDD in the
driver carrier and set it as unconfigured or global hot spare. The system event
log may be flooded with HDD fault entries.
Implication The SEL may be flooded with HDD fault entries when either of the two
scenarios above is used.
7