Power Supply Input Voltages
Table 4. CRPS Input Voltage
Parameter
Min
Rated
Max
Start up VAC Power Off VAC
110V
AC
90 V
rms
100-127 V
rms
140 V
rms
85 V
AC
± 4V
AC
70V
AC
±5V
AC
220V
AC
180 V
rms
200-240 V
rms
264 V
rms
Frequency 47 Hz 50/60 Hz 63 Hz
Power Supply Output Voltages
Table 5. CRPS Output Voltage
Parameter Min Nom Max Unit Tolerance
+12V
STB
+11.40V +12.000V +12.60V Vrms ±5%
+12V
+11.40V +12.000V +12.60V Vrms ±5%
System Environmental Specifications
The following table defines the system level operating and non-operating environmental limits.
Table 6. System Environmental Limits Summary
Parameter Limits
Operating Temperature +10°C to +35°C with the maximum rate of change not to exceed 10°C per hour.
Non-Operating Temperature -40°C to +70°C
Non-Operating Humidity 90%, non-condensing at 35°C
Acoustic noise Sound power:
3.5" HDD SKU: 6.9BA at idle and 7.4BA at active mode
2.5" HDD SKU: 6.5BA at idle and 7.07BA at active mode
In typical office ambient temperature. (23 +/- 2 degrees C).
Shock, operating Half sine, 2 g peak, 11 milliseconds
Shock, unpackaged Trapezoidal, 25 g, velocity change 205 inches/second (80 lbs to < 100 lbs)