Technical Product Specification
Intel
®
Server
Board S2600WP TPS Product Architecture Overview
3.4.20.1
MAC Address Definition
The Intel
®
Server Board S2600WP has the following four MAC addresses assigned to it at the
Intel
®
factory.
NIC 1 MAC address (for OS usage)
NIC 2 MAC address = NIC 1 MAC address + 1 (for OS usage)
BMC LAN channel 1 MAC address = NIC1 MAC address + 2
BMC LAN channel 2 MAC address = NIC1 MAC address + 3
BMC LAN channel 3 (Dedicated Server Management NIC) MAC address = NIC1
MAC address + 4
The Intel
®
Server Board S2600WP has a white MAC address sticker included with the board.
The sticker displays the NIC 1 MAC address in both bar code and alphanumeric formats.
3.4.20.2
LAN Manageability
Port 2 of the Intel
®
I350 NIC will be used by the BMC firmware to send management traffic.
In
standby in order to save power, Port 2 will be the only port to support Wake on LAN.
The
EEPROM is programmed to turn off this feature from the other ports in order to maximize power
savings during sleep states.
3.4.20.3
Wake-On-LAN
WOL is supported on the Intel
®
I350 LAN controller for all supported Sleep states.
3.4.20.4
LAN Connector Ordering
The Intel
®
I350 NIC is connected to independent RJ-45 ports for NIC 1 and NIC 2.
3.4.20.5
Intel
®
I350 Thermal Sensor
Intel
®
I350 NIC will have an integrated digital thermal sensor accessible through CSR and
manageability registers.
The thermal sensor can be programmed to trigger digital pins and
thermal throttling with hysteresis.
3.5
InfiniBand* Controller
Intel
®
Server Board S2600WPQ/S2600WPF are populated with a new generation
InfiniBand*/Ethernet adapter device. Mellanox* ConnectX*-3 supports Virtual Protocol
Interconnect
®
(VPI), providing single port 10/20/40/56 Gb/s InfiniBand* interfaces. The
functional diagram is as below:
Revision 1.6 Intel order number G44057-007 33