Technical Product Specification

Appendix B: Integrated BMC Sensor Tables Intel
®
Server
Board S2600WP TPS
Intel® Server Chassis
Fan
Domain
Major Components Cooled
(Temperature sensor number)
Fans
(Sensor number)
PS1 Temperature (5C)
PS2 Temperature (5D)
PS1 1b Fan Fail (A1h)
PS2 1a Fan Fail (A4h)
PS2 1b Fan Fail (A5h)
HSC Availability
FH2K16X25HSBP(PBA# G16566-XXX) for 16x2.5" HDD used in H2216WPJR/KR
FH2K12X35HSBP(PBA# G16567-XXX) for 12x3.5" HDD used in H2312WPJR/KR
Power unit and Power Supply support
Table 104. Intel
®
Server Chassis H23XXWP and H22XXWP Power Supply Support
Power Supply Type
Power Unit
Redundancy
Support
Power Supply FAN Sensors
1200W PSU
Yes
Power Supply 1 Fan Tachometer 1 #A0
Power Supply 1 Fan Tachometer 2 #A1
Power Supply 2 Fan Tachometer 1 #A4
Power Supply 2 Fan Tachometer 2 #A5
1600W PSU
Yes
Power Supply 1 Fan Tachometer 1 #A0
Power Supply 1 Fan Tachometer 2 #A1
Power Supply 2 Fan Tachometer 1 #A4
Power Supply 2 Fan Tachometer 2 #A5
Redundant Fans only for Intel
®
Server Chassis
None
Fan Fault LED support
Not Support
Memory Throttling support
Yes
Power Control Sources
When there is a fan failure and temperature critical event at the same time on Intel
®
Server
System H23XXWP or H22XXWP, BMC will turn the system power off.
Intel order number G44057-007 Revision 1.6