Technical Product Specification
Intel
®
Server
Board S2600WP TPS Appendix B: Integrated BMC Sensor Tables
Chassis-specific sensors
Table 102. Intel
®
Server Chassis H23XXWP and H22XXWP Specific Sensors
Intel® Server Chassis
Sensors
Supports
Sensors
H2312WPJR
H2312WPKR
H2216WPJR
H2216WPKR
System Fan 1a #30
Yes
System Fan 1b #31
Yes
System Fan 2a #32
Yes
System Fan 2b #33
Yes
System Fan 3a #34
Yes
System Fan 3b #35
Yes
FAN 1a Present #40
No
FAN 1b Present #41
No
FAN 2a Present #42
No
FAN 2b Present #43
No
FAN 3a Present #44
No
FAN 3b Present #45
No
Physical security (Chassis intrusion) Sensor #04 bit 0
No
FP interrupt (FP NMI Diag Int) Sensor #05
No
Hot-plug fan support
Not Support
Fan redundancy support
Not Support
Fan domain definition
Table 103. Intel
®
Server Chassis H23XXWP and H22XXWP Fan Domain Definition
Intel® Server Chassis
Fan
Domain
Major Components Cooled
(Temperature sensor number)
Fans
(Sensor number)
H2312WPJR
H2312WPKR
H2216WPJR
H2216WPKR
0
SSB Temp (22h)
BB BMC Temp( 23h)
P1 VR Temp (24h)
IB QDR Temp (25h)
IOM Temp (26h)
Exit Air Temp (2Eh)
Powerville Temp (2Fh)
DIMM Thrm Mrgn 1 (B0h)
DIMM Thrm Mrgn 2 (B1h)
DIMM Thrm Mrgn 3 (B2h)
DIMM Thrm Mrgn 4 (B3h)
P1 Therm Margin (74h)
P2 Therm Margin (75h)
System Fan 1a (30h)
System Fan 1b (31h)
System Fan 2a (32h)
System Fan 2b (33h)
System Fan 3a (34h)
System Fan 3b (35h)
2
HSBP 1 Temp (29h)
PS1 1a Fan Fail (A0h)
Revision 1.6 Intel order number G44057-007
199