Technical Product Specification
Appendix B: Integrated BMC Sensor Tables Intel
®
Server
Board S2600WP TPS
Full Sensor Name
(Sensor name in
SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/Offsets
Event
Data
Rearm
Stand-
by
Baseboard
+1.35V P2 Low
Voltage Memory
CD VDDQ
(BB +1.35 P2LV
CD)
E7h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A –
Baseboard
+3.3V Riser 1
Power Good
(BB +3.3 RSR1
PGD)
EAh
Platform
Specific
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A –
Baseboard
+3.3V Riser 2
Power Good
(BB +3.3 RSR2
PGD)
EBh
Platform
Specific
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A –
Hard Disk Drive
1 -15 Status
(HDD 1 - 15
Status)
F0h
-
FEh
Chassis-
specific
Drive Slot
0Dh
Sensor
Specific
6Fh
00 – Drive Presence
OK
As and
De
–
Trig
Offset
A X
01 – Drive Fault
Degraded
07 – Rebuild/Remap
in progress
Degraded
Below content describes Intel
®
Server Board S2600WP and Server System H2600WP specific information.
Product ID
Bytes 11:12 (product ID) of Get Device ID command response: 4Eh 00h
Intel order number G44057-007 Revision 1.6
196