Technical Product Specification
Intel
®
Server
Board S2600WP TPS Appendix B: Integrated BMC Sensor Tables
Full Sensor Name
(Sensor name in
SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/Offsets
Event
Data
Rearm
Stand-
by
Baseboard
+1.5V P2
Memory CD
VDDQ
(BB +1.5
P2MEM CD)
DBh All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A –
Baseboard
+1.8V Aux
(BB +1.8V AUX)
DCh All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A –
Baseboard
+1.1V Stand-by
(BB +1.1V
STBY)
DDh All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A –
Baseboard
CMOS Battery
(BB +3.3V Vbat)
DEh All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A –
Baseboard
+1.35V P1 Low
Voltage Memory
AB VDDQ
(BB +1.35 P1LV
AB)
E4h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A –
Baseboard
+1.35V P1 Low
Voltage Memory
CD VDDQ
(BB +1.35 P1LV
CD)
E5h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A –
Baseboard
+1.35V P2 Low
Voltage Memory
AB VDDQ
(BB +1.35 P2LV
AB)
E6h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A –
Revision 1.6 Intel order number G44057-007
195