Technical Product Specification

Appendix B: Integrated BMC Sensor Tables Intel
®
Server
Board S2600WP TPS
Full Sensor Name
(Sensor name in
SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/Offsets
Event
Data
Rearm
Stand-
by
Baseboard
+3.3V Auxiliary
(BB +3.3V AUX)
D4h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A X
Baseboard
+1.05V
Processor1 Vccp
(BB +1.05Vccp
P1)
D6h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A
Baseboard
+1.05V
Processor2 Vccp
(BB +1.05Vccp
P2)
D7h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A
Baseboard
+1.5V P1
Memory AB
VDDQ
(BB +1.5
P1MEM AB)
D8h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A
Baseboard
+1.5V P1
Memory CD
VDDQ
(BB +1.5
P1MEM CD)
D9h All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A
Baseboard
+1.5V P2
Memory AB
VDDQ
(BB +1.5
P2MEM AB)
DAh All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog R, T A
Intel order number G44057-007 Revision 1.6
194